The MS43 speaks BMW DS2 on the K-line: 9600 baud, 8 data bits, even parity, 1 stop bit, ECU address 0x12 [verified].
Everything on this page comes from the production SGBD MS430DS0.prg (MS 43.0 fuer M54 mit EWS 3, rev 2.00, 230 jobs). It was decompiled with ediabasx: ediabasx decompile --source MS430DS0.prg for near-source, and without --source for assembly. Request telegrams were recovered by tracing how each job patches its template before xsend. Unless a row says otherwise, the telegrams and layouts below are [verified, SGBD]: they are what the SGBD sends and parses, not captures from a car. The full data set (jobs, arguments, results, telegrams, status-block fields) is in data/sgbd_jobs.json.
Framing
[ADDR] [LEN] [CMD …] [XOR]LEN is the total frame length, including ADDR and XOR. XOR is the XOR of all preceding bytes. Telegrams in the tables below omit the XOR. EDIABAS appends it. Examples with checksum:
12 04 00 16 IDENT
12 05 0B 03 1F live-data block
12 09 06 00 07 00 00 08 12 read 8 bytes at 0x070000 (STATUS_DATENSATZ)The line is half-duplex, so every transmitted byte echoes back. The response is [12] [LEN] [STATUS] [data…] [XOR]. Byte offsets on this page are frame offsets (0 = address, 1 = length, 2 = status, 3 = first data byte), as the SGBD indexes them.
The SGBD's INITIALISIERUNG sets EDIABAS concept 6 (DS2) at 9600 baud. It does this with xsetpar(06 00 80 25 12 00 00 00 00 00 D0 07 64 00 14 00 00 00), i.e. 16-bit LE words 0x0006, 0x2580 (9600), 0x0012, 0, 0, 0x07D0 (2000), 0x0064 (100), 0x0014 (20), 0. The last words read as timing values in ms [inferred].
Status byte (JOBRESULT)
| Status | Text |
|---|---|
0xA0 | OKAY |
0x11 | AIF_NICHT_PROGRAMMIERT |
0xA1 | BUSY |
0xA2 | ERROR_ECU_REJECTED |
0xB0 | ERROR_ECU_PARAMETER |
0xB1 | ERROR_ECU_FUNCTION |
0xB2 | ERROR_ECU_NUMBER |
0xFF | ERROR_ECU_NACK |
0x01 | ERROR_ECU_FUNCTION_ANSTEUERBEDINGUNG_NICHT_ERFUELLT |
0x02 | ERROR_ECU_FUNCTION_UEBERGABEPARAMETER_UNGUELTIG |
0x05 | ERROR_ECU_FUNCTION NOCH NICHT GESTARTET |
0x06 | FUNCTION BEENDET; DATEN GUELTIG |
0x55 | ERROR_ECU_UNKNOWN_STATUSBYTE |
0xA1 is "busy, repeat". Several jobs (SEED_KEY, FS_LESEN) loop on it. The 0x01…0x06 codes are function-specific results that system checks and actuator tests return in the status position.
Baud rate
The SGBD only uses 9600. nfsx switches the MS43 to a higher rate with DS2 0x91 (91 00 96 00 01 = 38400; also 19200, 62500 and 125000) before bulk reads and writes, and switches back to 9600 afterwards [verified in nfsx code; nfsx default is 38400]. See Flashing.
Command bytes
| CMD | Use in MS430DS0 | Jobs |
|---|---|---|
00 | IDENT | IDENT, also called first by many jobs |
04 00 / 04 01 | fault memory: header / quick read, then entries | FS_QUICK_LESEN, FS_LESEN, FS_SELEKTIV_LOESCHEN |
05 | clear fault memory | FS_LOESCHEN |
06 | read memory: 06 <seg> <A23..A0> <N> | SPEICHER_LIN_LESEN, AIF_LESEN, STATUS_DATENSATZ, ECU_CONFIG |
07 <sub> | programming / protected functions (after SEED_KEY): 12 crank-sensor fault reset, 27 EWS start-value alignment. nfsx adds 02 write, 06 erase, 0F poll | KW_GEBER_FEHLER_RUECKSETZEN, MEHRFACHSTARTWERTABGLEICH |
0A | coding checksum | STATUS_CODIER_CHECKSUMME |
0B <blk> | status blocks (live data), see below | STATUS_* |
0B 02 0E 00 00 <ch> | raw ADC channel | STATUS_*_ADC, lambda voltages |
0D | system addresses (pointer table) | AIF_LESEN, IDENT_AIF |
0E / 0F | read / write test stamp (Prüfstempel, 3 bytes) | PRUEFSTEMPEL_LESEN/_SCHREIBEN |
14 01 | shadow fault memory | FS_SHADOW_LESEN |
22 <id> … | start actuator test / system check | STEUERN_*, START_SYSTEMCHECK_* |
23 <id> | stop actuator / function (00 = all [inferred]) | DIAGNOSE_STOP, STOP_SYSTEMCHECK_SEK_LUFT |
2B <id> | read system-check result | STATUS_SYSTEMCHECK_*, LESEN_SYSTEMCHECK_* |
40 / 41 / 42 | trim value read / adjust / store (01 CO, 02 idle, 0A consumption) | *_ABGLEICH_* |
43 <m1> <m2> | delete adaptations (bit mask) | ADAPT_*_LOESCHEN |
44 <id> | delete counters (02 pedal misuse, 03 cruise-control cut-off) | FUSSHEBELFEHLBEDIENUNG_LOESCHEN, ABSCHALTBEDINGUNG_FGR_LOESCHEN |
6C / 6D | EWS 3 sync mode set / status | STEUERN_SYNC_MODE, STATUS_SYNC_MODE |
90 42 4D 57 <z> | seed request ("BMW" + random index). 90 k0 k1 k2 k3 = key | SEED_KEY |
9E | keep diagnosis alive | DIAGNOSE_AUFRECHT |
9F | end diagnosis | DIAGNOSE_ENDE (sends 41 0A 00 first) |
Identification
IDENT (12 04 00)
IDENT cuts ASCII fields out of the response frame (offset, length) [verified, SGBD assembly]:
| Frame bytes | Result | Meaning |
|---|---|---|
| 3–9 | ID_BMW_NR | BMW part number (e.g. 7545150) |
| 10–11 | ID_HW_NR | hardware number |
| 12–13 | ID_COD_INDEX | coding index |
| 14–15 | ID_DIAG_INDEX | diagnosis index |
| 16–17 | ID_BUS_INDEX | bus index |
| 18–19 / 20–21 | ID_DATUM_KW / ID_DATUM_JAHR | manufacturing week / year |
| 22–31 | ID_LIEF_NR | supplier number |
| 32–33 | ID_SW_NR | software number |
| 34–35 | ID_AI_NR | change index |
| 37– | ID_PROD_NR | production number (length not confirmed) |
IDENT also returns MoTest parameters (ID_MOTOR, ID_LAMBDA_STEREO, ID_OBD2, ID_SG_HERSTELLER, …) and ID_EWS_SS. These come from constants in the job, not from the response.
System addresses (12 04 0D)
0D returns a table of 24-bit pointers, the same scheme as the BMS46 and MS42:
- Bytes 63–65: address of the AIF (application info field).
AIF_LESENreads 46 bytes (0x2E) from there with06and decodes the VIN, date, ZB number, programming-device serial, mileage and programming count [verified, SGBD]. - Bytes 57–59: hardware-reference pointer. nfsx reads 8 bytes from it and uses the first six (
111430on MS43) to tell MS43 from MS42 (111011) and GS20 [verified, nfsx].
Calibration reads
Two jobs read the calibration flash directly with 06:
STATUS_DATENSATZ:12 09 06 00 07 00 00 08returns 8 bytes at0x070000, the name of the applied data set.ECU_CONFIG: reads0B 94(variant bits, below), then 1 byte at0x070947[inferred: used forEGS_VORHANDEN].
SPEICHER_LIN_LESEN is a generic 06 read: arguments are a 24-bit address and a byte count.
Live data
Status blocks (12 05 0B xx)
Each STATUS_* job looks up its field in the SGBD table BETRIEBSWTAB, sends the block request and scales one field. Value = raw × factor + offset. Types: u8/s8, u16be/s16be (high byte first), u16le/s16le, bit. Signedness of s8 is read from the decoder (fix2flt of a byte register) [inferred]. STATUS_MESSWERTEBLOCK returns all 0B 03 fields at once.
Units are the SGBD's (GradKW = °crank, GradDK = ° throttle, GradPWG = ° pedal). Rows for 0B 96 and 0B A2 are in MS430DS0's table, but only Ms43_sp2.prg has jobs that read them.
12 05 0B 03
| Bytes | Name | Type | Value | Unit | Job |
|---|---|---|---|---|---|
| 3–4 | N | u16be | raw | 1/min | STATUS_MOTORDREHZAHL |
| 5 | VS | u8 | raw | km/h | STATUS_GESCHWINDIGKEIT |
| 6–7 | PVS_AV | u16be | raw × 0.0018311 | GradPWG | STATUS_PEDALWERT |
| 8–9 | TPS_AV_PRJ | u16be | raw × 0.0018311 | GradDK | STATUS_DK_WERT |
| 10–11 | MAF_KGH | u16be | raw × 0.25 | kg/h | STATUS_LMM_MASSE |
| 12 | TIA | u8 | raw × 0.75 − 48 | GradC | STATUS_AN_LUFTTEMPERATUR_MWB |
| 13 | TCO | u8 | raw × 0.75 − 48 | GradC | STATUS_MOTORTEMPERATUR_MWB |
| 14 | TOIL | u8 | raw × 0.796 − 48 | GradC | STATUS_OEL_TEMPERATUR_MWB |
| 15 | TCO_EX | u8 | raw × 0.75 − 48 | GradC | STATUS_KUEHLW_AUSL_TEMPERATUR_MWB |
| 16 | IGA_1 | u8 | −raw × 0.375 + 72 | GradKW | STATUS_ZUENDWINKEL |
| 17–18 | TI_BANK_1 | u16be | raw × 0.0053333 | ms | STATUS_EINSPRITZZEIT |
| 19–20 | ISAPWM_IS | s16be | raw × 0.0015 | % | STATUS_LL_INTEGRATOR |
| 21–22 | ISAPWM_ISA | u16be | raw × 0.0015 | % | STATUS_LL_STELLER_TV |
| 23 | CAM_AV_IN | u8 | raw × 0.375 + 60 | GradKW | STATUS_VANOS_NW_LAGE_EINLASS |
| 24 | CAM_AV_EX | s8 | −raw × 0.375 − 60 | GradKW | STATUS_VANOS_NW_LAGE_EINLASS |
| 25 | VB_IGK | u8 | raw × 0.10156 | V | STATUS_KL15 |
| 26–27 | LAM_1 | u16be | raw × 0.00001526 + 0.5 | - | STATUS_LAMBDA_INTEGRATOR_1 |
| 26–27 | LAM_1V | u16be | raw × 0.0015259 − 50 | % | STATUS_LAMBDA_INTEGRATOR_1 |
| 28–29 | LAM_2 | u16be | raw × 0.00001526 + 0.5 | - | STATUS_LAMBDA_INTEGRATOR_2 |
| 28–29 | LAM_2V | u16be | raw × 0.0015259 − 50 | % | STATUS_LAMBDA_INTEGRATOR_2 |
| 30 | LSHPWM_UP_1 | u8 | raw × 0.391 | % | STATUS_LS_VKAT_HEIZUNG_TV_1 |
| 31 | LSHPWM_UP_2 | u8 | raw × 0.391 | % | STATUS_LS_VKAT_HEIZUNG_TV_2 |
| 32 | LSHPWM_DOWN_1 | u8 | raw × 0.391 | % | STATUS_LS_NKAT_HEIZUNG_TV_1 |
| 33 | LSHPWM_DOWN_2 | u8 | raw × 0.391 | % | STATUS_LS_NKAT_HEIZUNG_TV_2 |
| 34–35 | MAF_MES | u16be | raw × 0.0212 | mg/HUB | STATUS_LAST |
| 36–37 | NL_2 | u16be | raw × 0.0000778 | V | STATUS_K_MW_2 |
| 38–39 | NL_5 | u16be | raw × 0.0000778 | V | STATUS_K_MW_5 |
| 40 | ECFPWM_ECF | u8 | raw × 0.39063 | % | STATUS_DREHZAHL_E_LUEFTER_VON_AC |
| 41–42 | AMP_MES | u16be | raw × 0.08292 | hPa | STATUS_LUFTDRUCK |
| 43 | VB | u8 | raw × 0.10156 | V | STATUS_UBATT |
12 05 0B 90
| Bytes | Name | Type | Value | Unit | Job |
|---|---|---|---|---|---|
| 3 | CAM_AV_IN | u8 | raw × 0.375 + 60 | GradKW | STATUS_VANOS_NW_LAGE_IST_SOLL_REF_EINLASS |
| 4 | CAM_SP_IN | u8 | raw × 0.375 + 60 | GradKW | STATUS_VANOS_NW_LAGE_IST_SOLL_REF_EINLASS |
| 5–6 | CAM_REF_IN | u16be | raw × 0.001465 + 60 | GradKW | STATUS_VANOS_NW_LAGE_IST_SOLL_REF_EINLASS |
| 7 | CAM_AD_IN | s8 | raw × 0.375 | GradKW | STATUS_VANOS_NW_FLANKENADAPTION |
| 8 | CAM_AV_IN_RAW | u8 | raw × 0.375 + 60 | GradKW | STATUS_VANOS_NW_ROHWERT |
| 9 | CAM_AV_EX | u8 | −raw × 0.375 − 60 | GradKW | STATUS_VANOS_NW_LAGE_IST_SOLL_REF_AUSLASS |
| 10 | CAM_SP_EX | u8 | −raw × 0.375 − 60 | GradKW | STATUS_VANOS_NW_LAGE_IST_SOLL_REF_AUSLASS |
| 11–12 | CAM_REF_EX | u16be | −raw × 0.001465 − 60 | GradKW | STATUS_VANOS_NW_LAGE_IST_SOLL_REF_AUSLASS |
| 13 | CAM_AD_EX | s8 | raw × 0.375 | GradKW | STATUS_VANOS_NW_FLANKENADAPTION |
| 14 | CAM_AV_EX_RAW | u8 | −raw × 0.375 − 60 | GradKW | STATUS_VANOS_NW_ROHWERT |
12 05 0B 91
| Bytes | Name | Type | Value | Unit | Job |
|---|---|---|---|---|---|
| 4–5 | TI_AD_ADD_MMV_1 | u16be | raw × 0.004 − 131.072 | ms | STATUS_ADD |
| 6–7 | TI_AD_FAC_MMV_1 | u16be | raw × 0.001526 − 50 | % | STATUS_MUL |
| 8–9 | TI_AD_ADD_MMV_2 | u16be | raw × 0.004 − 131.072 | ms | STATUS_ADD_2 |
| 10–11 | TI_AD_FAC_MMV_2 | u16be | raw × 0.001526 − 50 | % | STATUS_MUL_2 |
12 05 0B 92
| Bytes | Name | Type | Value | Unit | Job |
|---|---|---|---|---|---|
| 3–4 | ISAPWM_AD_MMV_IS | s16be | raw × 0.001526 | % | STATUS_LL_ADAPTION |
| 5–6 | ISAPWM_DRI_AD_MMV_IS | s16be | raw × 0.001526 | % | STATUS_LL_FS_ADAPTION |
| 7–8 | ISAPWM_ACCIN_AD_MMV_IS | s16be | raw × 0.001526 | % | STATUS_LL_KK_ADAPTION |
| 9–10 | PVS_AV_1 | u16be | raw × 0.0018311 | GradPWG | STATUS_PWG1_WINKEL |
| 11–12 | PVS_AV_2 | u16be | raw × 0.0018311 | GradPWG | STATUS_PWG2_WINKEL |
| 13–14 | TPS_AV_1 | u16be | raw × 0.007294 | GradDK | STATUS_DK1_WINKEL |
| 15–16 | TPS_AV_2 | u16be | raw × 0.007294 | GradDK | STATUS_DK2_WINKEL |
| 17–18 | V_TPS_AD_BOL_1 | u16be | raw × 0.0048828 | V | STATUS_DK_ADAP_UMA_MECH |
| 19–20 | V_TPS_AD_BOL_2 | u16be | raw × 0.0048828 | V | STATUS_DK_ADAP_UMA_MECH |
| 21–22 | V_TPS_AD_EL_BOL_1 | u16be | raw × 0.0048828 | V | STATUS_DK_ADAP_UMA_EL |
| 23–24 | V_TPS_AD_EL_BOL_2 | u16be | raw × 0.0048828 | V | STATUS_DK_ADAP_UMA_EL |
| 25–26 | V_TPS_AD_LIH_1 | u16be | raw × 0.0048828 | V | STATUS_DK_ADAP_UMA_LIH |
| 27–28 | V_TPS_AD_LIH_2 | u16be | raw × 0.0048828 | V | STATUS_DK_ADAP_UMA_LIH |
12 05 0B 93
| Bytes | Name | Type | Value | Unit | Job |
|---|---|---|---|---|---|
| 3–4 | FAC_RON_AD | u16be | raw × 0.00001526 | - | STATUS_KR |
12 05 0B 96
| Bytes | Name | Type | Value | Unit | Job |
|---|---|---|---|---|---|
| 3–4 | TQI_LIM_DIF_CTL_ACT_MAX | s16be | raw | Nm | STATUS_MAX_EINGRIFF |
| 5–6 | T_TQI_LIM_MAX_SAVE | u16be | raw × 0.01 | s | STATUS_MAX_ZEITEINGRIFF |
| 7–8 | TQI_LIM_CTR | u16be | raw | – | STATUS_ANZAHL_EINGRIFFE |
| 9 | E_N_32 | u8 | raw × 32 | 1/min | STATUS_MOTORDREHZAHL_EINGRIFF |
| 10 | E_TCO | u8 | raw × 0.75 − 48 | GradC | STATUS_MOTORTEMP_EINGRIFF |
| 11–12 | E_PVS_AV | u16be | raw × 0.0018311 | GradPWG | STATUS_PEDALWERT_EINGRIFF |
| 13–14 | E_TPS_AV_PRJ | u16be | raw × 0.0018311 | GradDK | STATUS_DK_WERT_EINGRIFF |
| 15–16 | E_ISAPWM_ISA | u16be | raw × 0.0015 | % | STATUS_LL_STELLER_EINGRIFF |
| 17–18 | E_MAF_KGH | u16be | raw × 0.25 | kg/h | STATUS_LMM_MASSE_EINGRIFF |
| 19–20 | E_AMP_MES | u16be | raw × 0.08292 | hPa | STATUS_LUFTDRUCK_EINGRIFF |
12 05 0B 97
| Bytes | Name | Type | Value | Unit | Job |
|---|---|---|---|---|---|
| 3–4 | CTR_DMTL_ACT | u16be | raw | – | STATUS_FREIGABEZAEHLER_DMTL |
| 5–6 | CTR_CUR_DMTL_REF_DIF_MAX | u16be | raw | – | STATUS_MESS_ABBRUCH_DMTL |
| 7–8 | CTR_ROUGH_LEAK_MES | u16be | raw | – | STATUS_GROBLECKMESSUNG_DMTL |
| 9–10 | CTR_SMALL_LEAK_MES | u16be | raw | – | STATUS_FEINLECKMESSUNG_DMTL |
| 11 | STATE_DMTL_EOL | u8 | raw | – | STATUS_DMTL_EOL |
12 05 0B 98
| Bytes | Name | Type | Value | Unit | Job |
|---|---|---|---|---|---|
| 3 | CTR_BLS_PVS | u8 | raw | – | STATUS_FUSSHEBELFEHLBEDIENUNG |
| 4–5 | KM_CTR_PVS_BLS | u16be | raw × 10 | km | STATUS_FUSSHEBELFEHLBEDIENUNG |
12 05 0B 99
| Bytes | Name | Type | Value | Unit | Job |
|---|---|---|---|---|---|
| 3–4 | CAT_DIAG_1 | u16be | raw × 0.0039 | – | STATUS_DIAGNOSEWERTE_KAT_LS_SEK |
| 5–6 | CAT_DIAG_2 | u16be | raw × 0.0039 | – | STATUS_DIAGNOSEWERTE_KAT_LS_SEK |
| 7–8 | VLS_CYC_AFR_RATIO_MV_1 | u16be | raw × 0.0039 | – | STATUS_DIAGNOSEWERTE_KAT_LS_SEK |
| 9–10 | VLS_CYC_AFR_RATIO_MV_2 | u16be | raw × 0.0039 | – | STATUS_DIAGNOSEWERTE_KAT_LS_SEK |
| 11–12 | VLS_CYC_AFL_RATIO_MV_1 | u16be | raw × 0.0039 | – | STATUS_DIAGNOSEWERTE_KAT_LS_SEK |
| 13–14 | VLS_CYC_AFL_RATIO_MV_2 | u16be | raw × 0.0039 | – | STATUS_DIAGNOSEWERTE_KAT_LS_SEK |
| 15–16 | SUM_AFL_VLS_SA_DIAG_1 | u16be | raw | – | STATUS_DIAGNOSEWERTE_KAT_LS_SEK |
| 17–18 | SUM_AFL_VLS_SA_DIAG_2 | u16be | raw | – | STATUS_DIAGNOSEWERTE_KAT_LS_SEK |
| 19–20 | SAF_DIAG_MAX | u16be | raw × 0.00390625 | kg/h | STATUS_DIAGNOSEWERTE_KAT_LS_SEK |
| 21–22 | SAF_DIAG_MIN | u16be | raw × 0.00390625 | kg/h | STATUS_DIAGNOSEWERTE_KAT_LS_SEK |
12 05 0B A2
| Bytes | Name | Type | Value | Unit | Job |
|---|---|---|---|---|---|
| 3–4 | N_LIM | u16be | raw × 0.15625 | 1/min | STATUS_MAX_UEBERDREHZAHL |
| 5–6 | TRT_N_LIM | u16be | raw × 6 | min | STATUS_BETRIEB_UEBERDREHZAHL |
| 7 | N_LIM_CRT | u8 | raw | – | STATUS_ZAEHLER_UEBERDREHZAHL |
12 05 0B A3
| Bytes | Name | Type | Value | Unit | Job |
|---|---|---|---|---|---|
| 7–8 | DIS_MIL | u16be | raw | km | STATUS_KM_MIL |
12 05 0B B0
| Bytes | Name | Type | Value | Unit | Job |
|---|---|---|---|---|---|
| 3–4 | K_PVS_AV | u16be | raw × 0.0018311 | GradPWG | STATUS_KALTTEST_1 |
| 5–6 | K_TPS_AV_PRJ | u16be | raw × 0.0018311 | GradDK | STATUS_KALTTEST_1 |
| 7–8 | K_ISAPWM_ISA | u16be | raw × 0.0015 | % | STATUS_KALTTEST_1 |
| 9–10 | K_MAF_KGH | u16be | raw × 0.25 | kg/h | STATUS_KALTTEST_1 |
| 11–12 | K_N | u16be | raw | 1/min | STATUS_KALTTEST_1 |
| 13–14 | K_NL_2 | u16be | raw × 0.0000778 | V | STATUS_KALTTEST_1 |
| 15–16 | K_NL_5 | u16be | raw × 0.0000778 | V | STATUS_KALTTEST_1 |
| 17 | K_TOIL | u8 | raw × 0.796 − 48 | GradC | STATUS_KALTTEST_1 |
| 18 | K_TCO | u8 | raw × 0.75 − 48 | GradC | STATUS_KALTTEST_1 |
| 19 | K_TIA | u8 | raw × 0.75 − 48 | GradC | STATUS_KALTTEST_1 |
12 05 0B B1
| Bytes | Name | Type | Value | Unit | Job |
|---|---|---|---|---|---|
| 3 | K_CAM_AV_IN | u8 | raw × 0.375 + 60 | GradKW | STATUS_KALTTEST_2 |
| 4 | K_CAM_AV_EX | u8 | −raw × 0.375 − 60 | GradKW | STATUS_KALTTEST_2 |
| 5–6 | K_CAM_REF_IN | u16be | raw × 0.001465 + 60 | GradKW | STATUS_KALTTEST_2 |
| 7–8 | K_CAM_REF_EX | u16be | −raw × 0.001465 − 60 | GradKW | STATUS_KALTTEST_2 |
| 9 | K_CAM_SP_IN | u8 | raw × 0.375 + 60 | GradKW | STATUS_KALTTEST_2 |
| 10 | K_CAM_SP_EX | u8 | −raw × 0.375 − 60 | GradKW | STATUS_KALTTEST_2 |
| 11 | K_CAM_AV_IN_RAW | u8 | raw × 0.375 + 60 | GradKW | STATUS_KALTTEST_2 |
| 12 | K_CAM_AV_EX_RAW | u8 | −raw × 0.375 − 60 | GradKW | STATUS_KALTTEST_2 |
| 13 | K_CAM_AD_IN | s8 | raw × 0.375 | GradKW | STATUS_KALTTEST_2 |
| 14 | K_CAM_AD_EX | s8 | raw × 0.375 | GradKW | STATUS_KALTTEST_2 |
Switch inputs (12 05 0B 04): STATUS_DIGITAL
Table BITS. BYTE is counted from the first data byte, i.e. frame offset 3 [inferred]. A flag is set when (byte & MASK) == VALUE.
| Byte | Mask | Value | Name |
|---|---|---|---|
| 0 | 0x80 | 0x80 | STAT_S_KO |
| 0 | 0x40 | 0x40 | STAT_S_AC |
| 0 | 0x20 | 0x20 | STAT_S_FGR |
| 0 | 0x10 | 0x10 | STAT_S_KUP |
| 0 | 0x08 | 0x08 | STAT_S_BLS |
| 0 | 0x04 | 0x04 | STAT_S_BLTS |
| 0 | 0x03 | 0x01 | STAT_LL |
| 0 | 0x03 | 0x02 | STAT_TL |
| 0 | 0x03 | 0x03 | STAT_VL |
| 1 | 0x80 | 0x80 | STAT_LAMBDAREG2 |
| 1 | 0x40 | 0x40 | STAT_LAMBDAREG1 |
| 1 | 0x20 | 0x20 | STAT_SCHUB_AB |
| 1 | 0x10 | 0x10 | STAT_SCHUB |
| 1 | 0x20 | 0x20 | STAT_SCHUB_AB |
| 1 | 0x08 | 0x08 | STAT_START |
| 1 | 0x04 | 0x04 | STAT_FS |
| 1 | 0x02 | 0x02 | STAT_EGS |
| 1 | 0x01 | 0x01 | STAT_CAN |
| 2 | 0x80 | 0x80 | STAT_SLV |
| 2 | 0x40 | 0x40 | STAT_SLP |
| 2 | 0x20 | 0x20 | STAT_SSP |
| 2 | 0x10 | 0x10 | STAT_RLV |
| 2 | 0x08 | 0x08 | STAT_KLAPPE |
| 2 | 0x04 | 0x04 | STAT_DMTL |
| 2 | 0x02 | 0x02 | STAT_R_KO |
| 2 | 0x01 | 0x01 | STAT_R_EKP |
| 3 | 0x80 | 0x80 | STAT_KAT_H |
| 3 | 0x40 | 0x40 | STAT_V_DMTL |
| 3 | 0x20 | 0x20 | STAT_EML_IL |
| 3 | 0x10 | 0x10 | STAT_MIL |
| 3 | 0x08 | 0x08 | STAT_TEV |
| 3 | 0x04 | 0x04 | STAT_DISA |
| 3 | 0x02 | 0x02 | STAT_ASC |
| 3 | 0x01 | 0x01 | STAT_TMOT |
| 4 | 0x80 | 0x80 | STAT_RUHE |
| 4 | 0x40 | 0x40 | STAT_VERZ |
| 4 | 0x20 | 0x20 | STAT_WIDERAUF |
| 4 | 0x10 | 0x10 | STAT_BESCHL |
| 4 | 0x08 | 0x08 | STAT_T_DOWN |
| 4 | 0x04 | 0x04 | STAT_T_UP |
| 4 | 0x02 | 0x02 | STAT_AUS |
| 4 | 0x01 | 0x01 | STAT_HAUS |
| 5 | 0x80 | 0x80 | STAT_VAN_AK |
| 5 | 0x40 | 0x40 | STAT_VAN_BR |
| 5 | 0x20 | 0x20 | STAT_VAN_PA |
| 5 | 0x10 | 0x10 | STAT_GEB_OK |
| 5 | 0x08 | 0x08 | STAT_LSH_NK2_B |
| 5 | 0x04 | 0x04 | STAT_LSH_NK1_B |
| 5 | 0x02 | 0x02 | STAT_LSH_VK2_B |
| 5 | 0x01 | 0x01 | STAT_LSH_VK1_B |
| 5 | 0x01 | 0x01 | STAT_LSH_VHP1 |
| 5 | 0x02 | 0x02 | STAT_LSH_VHP2 |
Cruise-control cut-off conditions (12 05 0B 05): STATUS_FGR_ABSCHALTUNG
| Byte | Mask | Value | Name |
|---|---|---|---|
| 0 | 0x40 | 0x40 | STAT_ENDSTUFE_DK |
| 0 | 0x20 | 0x20 | STAT_TIMEOUT_ASC |
| 0 | 0x10 | 0x10 | STAT_VS_SIGNAL |
| 0 | 0x08 | 0x08 | STAT_TPS_FEHLER |
| 0 | 0x04 | 0x04 | STAT_ISA_LIH |
| 0 | 0x02 | 0x02 | STAT_VS_PLAUSIBILISIERUNG |
| 0 | 0x01 | 0x01 | STAT_MONITORING_FEHLER |
| 1 | 0x20 | 0x20 | STAT_BREMSENFEHLER |
| 1 | 0x10 | 0x10 | STAT_TIMEOUT_EGS |
| 1 | 0x08 | 0x08 | STAT_MFL_FEHLER |
| 1 | 0x04 | 0x04 | STAT_KUPPLUNGSSCHALTER |
| 1 | 0x02 | 0x02 | STAT_DYNAMIKBEGRENZUNG_2 |
| 1 | 0x01 | 0x01 | STAT_DYNAMIKBEGRENZUNG_1 |
| 2 | 0x80 | 0x80 | STAT_MFL_BOTSCHAFT |
| 2 | 0x40 | 0x40 | STAT_BTS_BLS_PLAUSIBILITAET |
| 2 | 0x20 | 0x20 | STAT_DREHZAHLBEGRENZUNG |
| 2 | 0x10 | 0x10 | STAT_VS_FIL |
| 2 | 0x08 | 0x08 | STAT_UEBERTRETEN |
| 2 | 0x04 | 0x04 | STAT_HOCHLAUFSPERRE |
| 2 | 0x02 | 0x02 | STAT_BESCHLEUNIGUNGSUEBERWACHUNG |
| 2 | 0x01 | 0x01 | STAT_F_V1 |
| 3 | 0x10 | 0x10 | STAT_MFL_ANFORDERUNG_AUS |
| 3 | 0x08 | 0x08 | STAT_ESP |
| 3 | 0x04 | 0x04 | STAT_VS_SP_MAX_CRU |
| 3 | 0x02 | 0x02 | STAT_UEBERHOLFUNKTION |
| 3 | 0x01 | 0x01 | STAT_VS_ABWEICHUNG |
Variant configuration (12 05 0B 94): ECU_CONFIG, ABGAS_VARIANTE_LESEN
Here BYTE is a frame offset: the SGBD comment for CONFIG_GE says "Byte1 / 0x10" for the table's byte 3.
| Byte | Mask | Value | Name |
|---|---|---|---|
| 3 | 0x10 | 0x10 | CONFIG_GE |
| 3 | 0x04 | 0x04 | CONFIG_KAT |
| 3 | 0x02 | 0x02 | CONFIG_2FL |
| 3 | 0x01 | 0x01 | CONFIG_1FL |
| 4 | 0x80 | 0x80 | CONFIG_KOMBI |
| 4 | 0x20 | 0x20 | CONFIG_SSP |
| 4 | 0x10 | 0x10 | CONFIG_ELUEFTER |
| 4 | 0x08 | 0x08 | CONFIG_MIL |
| 4 | 0x04 | 0x04 | CONFIG_AKLAPPE |
| 4 | 0x02 | 0x02 | CONFIG_AC |
| 5 | 0x80 | 0x80 | CONFIG_REGEL |
| 5 | 0x40 | 0x40 | CONFIG_MONITOR |
| 5 | 0x08 | 0x08 | CONFIG_MFL |
| 5 | 0x02 | 0x02 | CONFIG_ASC |
| 5 | 0x20 | 0x20 | CONFIG_SLP |
| 5 | 0x10 | 0x10 | CONFIG_LDP |
| 6 | 0x20 | 0x20 | CONFIG_P_COIL |
| 6 | 0x01 | 0x01 | CONFIG_DMTL_H |
OBD readiness (12 05 0B A3): STATUS_DIGITAL_OBDII
| Byte | Mask | Value | Name |
|---|---|---|---|
| 0 | 0x80 | 0x80 | STAT_MIL |
| 1 | 0x04 | 0x04 | STAT_UB_KOMP |
| 1 | 0x02 | 0x02 | STAT_UB_TANK |
| 1 | 0x01 | 0x01 | STAT_UB_VER_AUS |
| 2 | 0x40 | 0x40 | STAT_UB_LAMBDASHZ |
| 2 | 0x20 | 0x20 | STAT_UB_LAMBDAS |
| 2 | 0x08 | 0x08 | STAT_UB_SE_LU |
| 2 | 0x04 | 0x04 | STAT_UB_TA_LE |
| 2 | 0x01 | 0x01 | STAT_UB_KAT |
| 3 | 0x40 | 0x00 | STAT_LAMBDASHZ_UB |
| 3 | 0x20 | 0x00 | STAT_LAMBDAS_UB |
| 3 | 0x08 | 0x00 | STAT_SE_LU_DIA |
| 3 | 0x04 | 0x00 | STAT_TA_LE_DIA |
| 3 | 0x01 | 0x00 | STAT_KAT_DIA |
STATUS_KM_MIL reads distance with MIL on from the same block (bytes 7–8, km).
ADC channels (12 09 0B 02 0E 00 00 <ch>)
The response is a 16-bit big-endian raw ADC value at bytes 3–4, scaled × 0.0048828 V (V_ADC_IN, 10-bit over 5 V). STATUS_PWG_POTI_SPANNUNG and STATUS_MDK_POTI_SPANNUNG read two channels each (sensor 1 and 2).
| Channel | Job(s) | Request |
|---|---|---|
0x00 | STATUS_AN_LUFTTEMPERATUR_ADC | 12 09 0B 02 0E 00 00 00 |
0x01 | STATUS_L_SONDE, STATUS_LS_VKAT_SIGNAL_1 | 12 09 0B 02 0E 00 00 01 |
0x02 | STATUS_L_SONDE_2, STATUS_LS_VKAT_SIGNAL_2 | 12 09 0B 02 0E 00 00 02 |
0x03 | STATUS_MOTORTEMPERATUR_ADC | 12 09 0B 02 0E 00 00 03 |
0x04 | STATUS_ZSI | 12 09 0B 02 0E 00 00 04 |
0x05 | STATUS_OEL_TEMPERATUR_ADC | 12 09 0B 02 0E 00 00 05 |
0x06 | STATUS_LMM_SPANNUNG | 12 09 0B 02 0E 00 00 06 |
0x07 | STATUS_UBATT_ADC | 12 09 0B 02 0E 00 00 07 |
0x08 | STATUS_PWG_POTI_SPANNUNG | 12 09 0B 02 0E 00 00 08 |
0x09 | STATUS_PWG_POTI_SPANNUNG | 12 09 0B 02 0E 00 00 09 |
0x0A | STATUS_MDK_POTI_SPANNUNG | 12 09 0B 02 0E 00 00 0A |
0x0B | STATUS_MDK_POTI_SPANNUNG | 12 09 0B 02 0E 00 00 0B |
0x10 | STATUS_KUEHLW_AUSL_TEMPERATUR_ADC | 12 09 0B 02 0E 00 00 10 |
0x17 | STATUS_KLOPF_ADC1 | 12 09 0B 02 0E 00 00 17 |
0x18 | STATUS_KLOPF_ADC2 | 12 09 0B 02 0E 00 00 18 |
0x19 | STATUS_L_SONDE_H, STATUS_LS_NKAT_SIGNAL_1 | 12 09 0B 02 0E 00 00 19 |
0x1A | STATUS_L_SONDE_2_H, STATUS_LS_NKAT_SIGNAL_2 | 12 09 0B 02 0E 00 00 1A |
Actuator tests (12 xx 22 <id> …)
22 <id> <value> starts a test. DIAGNOSE_STOP (23 <id>) ends one, and 23 00 probably ends all of them [inferred]. xx bytes come from the job argument. Where BETRIEBSWTAB gives an encoding, the SGBD sends round(value / factor). For example, STEUERN_E_LUEFTER sends duty % / 0.39063. On/off arguments are 00/FF (STEUERN_DISA: 00 off, FF on). STEUERN_EV_n (no argument) fires injector n with the template's fixed 5D 0A. The _ARG variants take an on-time (TI_DS2, 0–2.72 ms, ÷ 0.0106667) and a period (TP_TI_DS2, 0–2550 ms, ÷ 10). STEUERN_EV_n_AUS cuts injector n with a bit mask (01…20) via id 82.
| Job | Request | Argument | Encoding (SGBD) |
|---|---|---|---|
STEUERN_SEK_PUMPE | 12 06 22 81 xx | PUMPE_EIN_AUS | – |
STEUERN_EV_SELEKTIV_AUSBLENDEN | 12 06 22 82 xx | ZYLINDER_AUSWAHL | – |
STEUERN_EV_1_AUS | 12 06 22 82 01 | – | – |
STEUERN_EV_2_AUS | 12 06 22 82 02 | – | – |
STEUERN_EV_3_AUS | 12 06 22 82 04 | – | – |
STEUERN_EV_4_AUS | 12 06 22 82 08 | – | – |
STEUERN_EV_5_AUS | 12 06 22 82 10 | – | – |
STEUERN_EV_6_AUS | 12 06 22 82 20 | – | – |
STEUERN_KF_THERMOSTAT | 12 06 22 83 xx | TASTVERHAELTNIS | ECTPWM: value / 0.3922 % |
STEUERN_EKP | 12 06 22 84 xx | PUMPE_EIN_AUS | – |
STEUERN_DMTL_MOTOR | 12 06 22 86 xx | MOTOR_EIN_AUS | – |
STEUERN_DMTL_VENTIL | 12 06 22 87 xx | VENTIL_AUF_ZU | – |
STEUERN_DISA | 12 06 22 88 xx | DISA_EIN_AUS | – |
STEUERN_DMTL_HEIZUNG | 12 06 22 8B 0012 06 22 8B FF | SCHALTEN | – |
STEUERN_ABGASKLAPPE | 12 06 22 8A xx | AKL_AUF_ZU | – |
STEUERN_E_LUEFTER | 12 06 22 8E xx | TASTVERHAELTNIS | ECF_PWM_ECF: value / 0.39063 % |
STEUERN_E_LUEFTER_ECOS | 12 04 0012 06 22 8E xx | – | – |
STEUERN_LL_DREHZAHL_VERSTELLEN | 12 06 22 90 xx | DREHZAHL | N_SP_IS: value / 32 1/min |
STEUERN_MIL | 12 06 22 91 xx | MIL_EIN_AUS | – |
STEUERN_TEMP_ANZEIGE_KOMBI | 12 07 22 92 xx xx | TEMPERATUR, UEBERTEMP_EIN_AUS | TCO_CAN: value / 0.75 GradC |
STEUERN_KO | 12 06 22 94 xx | KOMPRESSOR_EIN_AUS | – |
STEUERN_DK_WINKEL | 12 07 22 95 xx xx | WINKELVORGABE | TPS_SP: value / 0.007294 GradDK |
STEUERN_LS_HEIZUNG_VKAT_BANK1 | 12 06 22 9A xx | TASTVERHAELTNIS | LSHPWM_UP_1: value / 0.391 % |
STEUERN_LS_HEIZUNG_VKAT_BANK2 | 12 06 22 9B xx | TASTVERHAELTNIS | LSHPWM_UP_2: value / 0.391 % |
STEUERN_LS_HEIZUNG_NKAT_BANK1 | 12 06 22 9C xx | TASTVERHAELTNIS | LSHPWM_DOWN_1: value / 0.391 % |
STEUERN_LS_HEIZUNG_NKAT_BANK2 | 12 06 22 9D xx | TASTVERHAELTNIS | LSHPWM_DOWN_2: value / 0.391 % |
STEUERN_VANOS_E_VERSTELLZEIT | 12 07 22 A0 xx xx12 05 0B 90 | POS1, POS2 | – |
STEUERN_VANOS_A_VERSTELLZEIT | 12 07 22 A1 xx xx12 05 0B 90 | POS1, POS2 | – |
STEUERN_VANOS_E_DICHTHEIT | 12 07 22 A2 xx xx12 05 0B 90 | POS, TIME | – |
STEUERN_VANOS_A_DICHTHEIT | 12 07 22 A3 xx xx12 05 0B 90 | POS, TIME | – |
STEUERN_VANOS_E_SOLLWERT | 12 06 22 A4 xx12 05 0B 90 | NW_SPREIZUNG | IVVTPWM_IN: value / 0.3906 % |
STEUERN_VANOS_A_SOLLWERT | 12 06 22 A5 xx12 05 0B 90 | NW_SPREIZUNG | IVVTPWM_EX: value / 0.3906 % |
STEUERN_VANOS_E_VENTIL | 12 06 22 A6 xx | TASTVERHAELTNIS | – |
STEUERN_VANOS_A_VENTIL | 12 06 22 A7 xx | TASTVERHAELTNIS | – |
STEUERN_EV_1_ARG | 12 07 22 B1 xx xx | ANSTEUERZEIT, PERIODENDAUER | TI_DS2: value / 0.0106667 %; TP_TI_DS2: value / 10 % |
STEUERN_EV_2_ARG | 12 07 22 B2 xx xx | ANSTEUERZEIT, PERIODENDAUER | TI_DS2: value / 0.0106667 %; TP_TI_DS2: value / 10 % |
STEUERN_EV_3_ARG | 12 07 22 B3 xx xx | ANSTEUERZEIT, PERIODENDAUER | TI_DS2: value / 0.0106667 %; TP_TI_DS2: value / 10 % |
STEUERN_EV_4_ARG | 12 07 22 B4 xx xx | ANSTEUERZEIT, PERIODENDAUER | TI_DS2: value / 0.0106667 %; TP_TI_DS2: value / 10 % |
STEUERN_EV_5_ARG | 12 07 22 B5 xx xx | ANSTEUERZEIT, PERIODENDAUER | TI_DS2: value / 0.0106667 %; TP_TI_DS2: value / 10 % |
STEUERN_EV_6_ARG | 12 07 22 B6 xx xx | ANSTEUERZEIT, PERIODENDAUER | TI_DS2: value / 0.0106667 %; TP_TI_DS2: value / 10 % |
STEUERN_EV_1 | 12 07 22 B1 5D 0A | – | – |
STEUERN_EV_2 | 12 07 22 B2 5D 0A | – | – |
STEUERN_EV_3 | 12 07 22 B3 5D 0A | – | – |
STEUERN_EV_4 | 12 07 22 B4 5D 0A | – | – |
STEUERN_EV_5 | 12 07 22 B5 5D 0A | – | – |
STEUERN_EV_6 | 12 07 22 B6 5D 0A | – | – |
STEUERN_LL_STELLER | 12 06 22 B7 xx | TASTVERHAELTNIS | ISAPWM_ISA_BYTE: value / 0.3906 % |
STEUERN_SEK_VENTIL | 12 06 22 BA xx | VENTIL_AUF_ZU | – |
STEUERN_TEV | 12 06 22 BB xx | TASTVERHAELTNIS | CPPWM_CPS_BYTE: value / 0.3906 % |
STEUERN_DMTL_TEV | 12 06 22 BB xx12 06 22 87 xx12 06 22 86 xx | TASTVERHAELTNIS | – |
STEUERN_LL_MANIPULATION | 12 06 22 90 xx12 05 0B 03 | DREHZAHL | – |
Ids A0–A3 start VANOS adjustment-time and leak tests, whose results are read with 2B A0–A3. A4/A5 set intake/exhaust cam targets and A6/A7 drive the VANOS valves directly.
System checks (22 xx start, 2B xx result)
START_SYSTEMCHECK_* sends 12 05 22 <id>. The matching STATUS_/LESEN_SYSTEMCHECK_* reads 12 05 2B <id>, and the status byte probably carries 0x05 (not started) / 0x06 (finished, data valid) from JOBRESULT [inferred]. Ids: 01 purge valve (TEV), 02 secondary air, 03 tank leak (DMTL), 04 lambda heaters, 05 misfire / running roughness, 06 swapped lambda sensors. Result layouts:
12 07 22 95 00 00
| Bytes | Name | Type | Value | Unit | Job |
|---|---|---|---|---|---|
| 5–6 | TPS_SP | u16be | raw × 0.007294 | GradTPS | STEUERN_KTEST_MDK |
12 05 2B 01
| Bytes | Name | Type | Value | Unit | Job |
|---|---|---|---|---|---|
| 4 | SUM_CPPWM_DIAGCPS | u8 | raw | – | STATUS_SYSTEMCHECK_TEV |
| 5 | SUM_DIAG_DIAGCPS | u8 | raw | – | STATUS_SYSTEMCHECK_TEV |
12 05 2B 02
| Bytes | Name | Type | Value | Unit | Job |
|---|---|---|---|---|---|
| 4–5 | SAF_DIAG_MAX | u16be | raw × 0.00390625 | kg/h | STATUS_SYSTEMCHECK_SEK_LUFT_SAF |
| 4–5 | SUM_AFL_VLS_SA_DIAG_1 | u16be | raw | – | STATUS_SYSTEMCHECK_SEK_LUFT |
| 6–7 | SAF_DIAG_MIN | u16be | raw × 0.00390625 | kg/h | STATUS_SYSTEMCHECK_SEK_LUFT_SAF |
| 6–7 | SUM_AFL_VLS_SA_DIAG_2 | u16be | raw | – | STATUS_SYSTEMCHECK_SEK_LUFT |
| 8–9 | SA_FLAGS | u16be | raw | – | STATUS_SYSTEMCHECK_SEK_LUFT |
12 05 2B 03
| Bytes | Name | Type | Value | Unit | Job |
|---|---|---|---|---|---|
| 5–6 | CUR_DMTL_REF_LEAK | u16be | raw × 0.006104 | mA | STATUS_SYSTEMCHECK_DMTL |
| 7–8 | CUR_DMTL_ROUGH_LEAK | u16be | raw × 0.006104 | mA | STATUS_SYSTEMCHECK_DMTL |
| 9–10 | CUR_DMTL | u16be | raw × 0.006104 | mA | STATUS_SYSTEMCHECK_DMTL |
12 05 2B 04
| Bytes | Name | Type | Value | Unit | Job |
|---|---|---|---|---|---|
| 4 | VLS_MMV_MIN_UP_1 | u8 | raw × 0.005 | V | STATUS_SYSTEMCHECK_SONDENHEIZUNG |
| 5 | VLS_MMV_MAX_UP_1 | u8 | raw × 0.005 | V | STATUS_SYSTEMCHECK_SONDENHEIZUNG |
| 6 | VLS_MMV_MIN_UP_2 | u8 | raw × 0.005 | V | STATUS_SYSTEMCHECK_SONDENHEIZUNG |
| 7 | VLS_MMV_MAX_UP_2 | u8 | raw × 0.005 | V | STATUS_SYSTEMCHECK_SONDENHEIZUNG |
| 8–9 | R_LS_UP_1 | u16be | raw | Ohm | STATUS_SYSTEMCHECK_SONDENHEIZUNG |
| 10–11 | R_LS_UP_2 | u16be | raw | Ohm | STATUS_SYSTEMCHECK_SONDENHEIZUNG |
| 12–13 | R_LS_DOWN_1 | u16be | raw | Ohm | STATUS_SYSTEMCHECK_SONDENHEIZUNG |
| 14–15 | R_LS_DOWN_2 | u16be | raw | Ohm | STATUS_SYSTEMCHECK_SONDENHEIZUNG |
12 05 2B 05
| Bytes | Name | Type | Value | Unit | Job |
|---|---|---|---|---|---|
| 4–5 | ER_QUO_1 | s16be | raw × 0.00122 | - | STATUS_SYSTEMCHECK_LAUFUNRUHE |
| 6–7 | ER_QUO_5 | s16be | raw × 0.00122 | - | STATUS_SYSTEMCHECK_LAUFUNRUHE |
| 8–9 | ER_QUO_3 | s16be | raw × 0.00122 | - | STATUS_SYSTEMCHECK_LAUFUNRUHE |
| 10–11 | ER_QUO_6 | s16be | raw × 0.00122 | - | STATUS_SYSTEMCHECK_LAUFUNRUHE |
| 12–13 | ER_QUO_2 | s16be | raw × 0.00122 | - | STATUS_SYSTEMCHECK_LAUFUNRUHE |
| 14–15 | ER_QUO_4 | s16be | raw × 0.00122 | - | STATUS_SYSTEMCHECK_LAUFUNRUHE |
| 16–17 | MIS_SUM_CARB_1 | u16be | raw | - | STATUS_SYSTEMCHECK_LAUFUNRUHE |
| 18–19 | MIS_SUM_CARB_5 | u16be | raw | - | STATUS_SYSTEMCHECK_LAUFUNRUHE |
| 20–21 | MIS_SUM_CARB_3 | u16be | raw | - | STATUS_SYSTEMCHECK_LAUFUNRUHE |
| 22–23 | MIS_SUM_CARB_6 | u16be | raw | - | STATUS_SYSTEMCHECK_LAUFUNRUHE |
| 24–25 | MIS_SUM_CARB_2 | u16be | raw | - | STATUS_SYSTEMCHECK_LAUFUNRUHE |
| 26–27 | MIS_SUM_CARB_4 | u16be | raw | - | STATUS_SYSTEMCHECK_LAUFUNRUHE |
12 05 2B 06
| Bytes | Name | Type | Value | Unit | Job |
|---|---|---|---|---|---|
| 4 | VLS_EOL_R_1 | u8 | raw × 0.005 | V | STATUS_SYSTEMCHECK_VERTAUSCHT_LAMBDASONDEN |
| 5 | VLS_EOL_R_2 | u8 | raw × 0.005 | V | STATUS_SYSTEMCHECK_VERTAUSCHT_LAMBDASONDEN |
| 6 | VLS_CAT_EOL_R_1 | u8 | raw × 0.005 | V | STATUS_SYSTEMCHECK_VERTAUSCHT_LAMBDASONDEN |
| 7 | VLS_CAT_EOL_R_2 | u8 | raw × 0.005 | V | STATUS_SYSTEMCHECK_VERTAUSCHT_LAMBDASONDEN |
| 8 | VLS_EOL_L_1 | u8 | raw × 0.005 | V | STATUS_SYSTEMCHECK_VERTAUSCHT_LAMBDASONDEN |
| 9 | VLS_EOL_L_2 | u8 | raw × 0.005 | V | STATUS_SYSTEMCHECK_VERTAUSCHT_LAMBDASONDEN |
| 10 | VLS_CAT_EOL_L_1 | u8 | raw × 0.005 | V | STATUS_SYSTEMCHECK_VERTAUSCHT_LAMBDASONDEN |
| 11 | VLS_CAT_EOL_L_2 | u8 | raw × 0.005 | V | STATUS_SYSTEMCHECK_VERTAUSCHT_LAMBDASONDEN |
| 12–13 | MAF_INT_VLS_EOL | u16be | raw × 0.0277778 | g | STATUS_SYSTEMCHECK_VERTAUSCHT_LAMBDASONDEN |
12 05 2B 81
| Bytes | Name | Type | Value | Unit | Job |
|---|---|---|---|---|---|
| 4–5 | SAF_KGH | u16be | raw × 0.015625 | kg/h | STATUS_SYSTEMCHECK_SEK_LUFT_PUMPE |
12 05 2B 83
| Bytes | Name | Type | Value | Unit | Job |
|---|---|---|---|---|---|
| 5 | ECTPWM_STAT | u8 | raw × 0.3922 | % | STATUS_SYSTEMCHECK_KENNFELDTHERMOSTAT |
12 05 2B 95
| Bytes | Name | Type | Value | Unit | Job |
|---|---|---|---|---|---|
| 4–5 | TPS_AV | u16be | raw × 0.007294 | GRAD DK | STATUS_SYSTEMCHECK_DK_WINKEL |
12 05 2B A0
| Bytes | Name | Type | Value | Unit | Job |
|---|---|---|---|---|---|
| 4 | T_CAM_IN_LATE_EARLY | u8 | raw × 0.01 | s | STATUS_VERSTELLZEIT_MESS_VANOS_E |
| 5 | T_CAM_IN_EARLY_LATE | u8 | raw × 0.01 | s | STATUS_VERSTELLZEIT_MESS_VANOS_E |
12 05 2B A1
| Bytes | Name | Type | Value | Unit | Job |
|---|---|---|---|---|---|
| 4 | T_CAM_EX_LATE_EARLY | u8 | raw × 0.01 | s | STATUS_VERSTELLZEIT_MESS_VANOS_A |
| 5 | T_CAM_EX_EARLY_LATE | u8 | raw × 0.01 | s | STATUS_VERSTELLZEIT_MESS_VANOS_A |
12 05 2B A2
| Bytes | Name | Type | Value | Unit | Job |
|---|---|---|---|---|---|
| 4 | CAM_DIF_THICK_IN | s8 | raw × 0.375 | GradKW | STATUS_DICHTHEIT_MESS_VANOS_E |
12 05 2B A3
| Bytes | Name | Type | Value | Unit | Job |
|---|---|---|---|---|---|
| 4 | CAM_DIF_THICK_EX | s8 | raw × 0.375 | GradKW | STATUS_DICHTHEIT_MESS_VANOS_A |
12 05 40 0A
| Bytes | Name | Type | Value | Unit | Job |
|---|---|---|---|---|---|
| 3 | C_DS2_FCO_FAC | s8 | raw × 0.001 | – | VERBRAUCH_ABGLEICH_LESEN |
Adaptation resets (12 06 43 <m1> <m2>)
Bit masks recovered from the job code [verified, SGBD]:
| Job | Telegram | Resets |
|---|---|---|
ADAPT_LOESCHEN | 12 06 43 FF FF | everything |
ADAPT_LAUFUNRUHE_LOESCHEN | 12 06 43 80 00 | running roughness (misfire segment adaptation) |
ADAPT_SCHLIESSZEIT_LOESCHEN | 12 06 43 40 00 | dwell (closing time) |
ADAPT_LM_SENSOR_LOESCHEN | 12 06 43 10 00 | air-mass sensor |
ADAPT_DROSSELKLAPPE_LOESCHEN | 12 06 43 08 00 | throttle |
ADAPT_LAMBDA_LOESCHEN | 12 06 43 04 00 | mixture (lambda) |
ADAPT_LEERLAUF_LOESCHEN | 12 06 43 02 00 | idle |
ADAPT_KLOPFREGELUNG_LOESCHEN | 12 06 43 01 00 | knock control |
ADAPT_VARIANTEN_LOESCHEN | 12 06 43 00 01 | learned variant (configuration) |
Related: KW_GEBER_FEHLER_RUECKSETZEN runs SEED_KEY, then 12 09 07 12 00 00 00 00 (crank sensor fault / segment reset). FUSSHEBELFEHLBEDIENUNG_LOESCHEN (44 02) and ABSCHALTBEDINGUNG_FGR_LOESCHEN (44 03) clear counters. Ms43_sp2 adds MOMENTEN_EINGRIFF_LOESCHEN (12 04 44).
Trim adjustments
40 <id> reads, 41 <id> <value> adjusts temporarily, 42 <id> stores. Ids: 01 CO trim, 02 idle speed, 0A consumption (fuel-consumption display correction). VERBRAUCH_ABGLEICH_LESEN reads C_DS2_FCO_FAC from 12 05 40 0A, byte 3, s8 × 0.001. VERBRAUCH_ABGLEICH_PROGRAMMIEREN sends nothing in this SGBD revision (stub). DIAGNOSE_ENDE sends 41 0A 00 before 9F, so an un-stored consumption adjustment is dropped when diagnosis ends [inferred].
Coding
MS430DS0 has no coding jobs (no CODIERDATEN_* / CODIERUNG_*), and the local NCSEXPER and E46 v74 daten coding files have no DME (MS43) module. Vehicle options are set in the calibration (or learned over CAN). They can be read with ECU_CONFIG / ABGAS_VARIANTE_LESEN (0B 94) and the learned part reset with ADAPT_VARIANTEN_LOESCHEN. STATUS_CODIER_CHECKSUMME (12 04 0A) returns a single checksum value. Calibration changes are flashed, see Flashing.
Security access (SEED_KEY)
SEED_KEY sends 12 08 90 42 4D 57 <Z>. Z (result Z_ZAHL) is a random index the job derives from the clock and folds into a small range. The job retries while the ECU answers 0xA1 and submits the 4-byte key with 12 08 90 k0 k1 k2 k3. The key derivation, as nfsx implements it, is on the Flashing page. Jobs that need security access (KW_GEBER_FEHLER_RUECKSETZEN, programming) run it first.
Job table
All 230 jobs, in SGBD order within each group. Request shows the telegram(s) the job sends, without XOR. xx = filled from an argument or at run time. A job that takes arguments may overwrite trailing 00 template bytes, which then still show as 00. Status jobs often also send 12 04 00 first; it's listed when the SGBD does that. ¹ = job name appears in the INPA script ms430.ipo (string match, so heuristic).
Identification, session and memory (17)
| Job | Request | Arguments | Results | SGBD comment |
|---|---|---|---|---|
INFO ¹ | – | – | ECU, ORIGIN, REVISION, AUTHOR +3 more | Information SGBD |
INITIALISIERUNG ¹ | – | – | DONE | Default Init-Job |
ECU_CONFIG | 12 05 0B 9412 04 0012 09 06 00 07 09 47 xx | – | GE_VORHANDEN, KAT_VORHANDEN, ZWEI_FLUTIG, EIN_FLUTIG +12 more | Ident-Daten fuer DME |
ABGAS_VARIANTE_LESEN ¹ | 12 05 0B 94 | – | ABGAS_VARIANTE_WERT, ABGAS_VARIANTE_ZWEIFL_WERT, ABGAS_VARIANTE_EINFL_WERT, ABGAS_VARIANTE_REGEL_WERT +2 more | Auslesen der Abgasvariante |
PRUEFSTEMPEL_LESEN | 12 04 0E | – | BYTE1, BYTE2, BYTE3 | Auslesen des Pruefstempels |
PRUEFSTEMPEL_SCHREIBEN | 12 07 0F xx xx xx | BYTE1, BYTE2, BYTE3 | – | Beschreiben des Pruefstempels Es muessen immer alle drei Argumente im Bereich von 0-255 bzw. 0x00-0xFF uebergeben werden. |
SPEICHER_LIN_LESEN ¹ | 12 09 06 00 xx xx xx xx | SPEICHER_LIN_LESEN_ADRESSE, SPEICHER_LIN_LESEN_ANZAHL_BYTE | SPEICHER_LIN_LESEN_WERT | Beliebige RAM - Zellen auslesen |
AIF_LESEN ¹ | 12 04 0D12 09 06 00 xx xx xx 2E | – | AIF_FG_NR, AIF_DATUM, AIF_AENDERUNGS_INDEX, AIF_SW_NR +6 more | Auslesen des Anwender-Info-Feldes |
IDENT ¹ | 12 04 00 | – | ID_BMW_NR, ID_HW_NR, ID_COD_INDEX, ID_DIAG_INDEX +15 more | Ident-Daten fuer DME |
IDENT_AIF | 12 04 0012 04 0D12 09 06 00 xx xx xx 2E | – | ID_BMW_NR, ID_HW_NR, ID_COD_INDEX, ID_DIAG_INDEX +17 more | Ident und AIF zusammen lesen |
PRUEFCODE_LESEN | 12 04 0012 04 0D12 09 06 00 xx xx xx 2E12 05 04 0012 05 04 01 | – | PRUEFCODE | Pruefcode-Daten in Hex auslesen |
DIAGNOSE_STOP | 12 05 23 xx | FUNKTIONSBYTE | – | Einzelne Diagnosefunktionen beenden |
SEED_KEY | 12 08 90 42 4D 57 xx12 08 90 xx xx xx xx | – | STAT_SEED_KEY, Z_ZAHL | Schutzmechanismus SEED_KEY |
DIAGNOSE_AUFRECHT | 12 04 9E | – | – | Diagnosefunktionen erhalten |
DIAGNOSE_ENDE ¹ | 12 06 41 0A xx12 04 9F | – | – | Diagnose beenden |
STATUS_CODIER_CHECKSUMME | 12 04 0A | – | STAT_CHECKSUMME_WERT | Codier - Checksumme abfragen |
STATUS_DATENSATZ | 12 09 06 00 07 00 00 08 | – | DATENSATZ | applizierten DatenSatz auslesen |
Fault memory (5)
| Job | Request | Arguments | Results | SGBD comment |
|---|---|---|---|---|
FS_LESEN | 12 04 0012 05 04 0012 05 04 01 | – | F_ANZ_NR, F_ORT_NR, F_ORT_TEXT, F_HFK +43 more | Auslesen des Fehlerspeichers |
FS_SELEKTIV_LOESCHEN | 12 05 04 0012 05 04 0112 04 05 | FEHLER_0, FEHLER_1, FEHLER_2, FEHLER_3, FEHLER_4, FEHLER_5, FEHLER_6, FEHLER_7, FEHLER_8, FEHLER_9 | – | Auslesen des Fehlerspeichers |
FS_QUICK_LESEN ¹ | 12 05 04 00 | – | F_ANZ_NR, F_BSZ_AKT, F_BSZ_ALT | Auslesen des QUICK Fehlerspeichers |
FS_SHADOW_LESEN ¹ | 12 05 14 01 | – | F_ANZ_NR, F_ORT_NR, F_ORT_TEXT, F_HFK +37 more | Auslesen des Fehlerspeichers |
FS_LOESCHEN ¹ | 12 04 05 | – | – | Loeschen des Fehlerspeichers |
Live data (STATUS_*) (93)
| Job | Request | Arguments | Results | SGBD comment |
|---|---|---|---|---|
STATUS_AN_LUFTTEMPERATUR_ADC | 12 09 0B 02 0E 00 00 00 | – | STAT_AN_LUFTTEMPERATUR_ADC_WERT, STAT_AN_LUFTTEMPERATUR_ADC_EINH | Temperatur Ansaugluft ueber ADC-Kanal lesen |
STATUS_L_SONDE ¹ | 12 09 0B 02 0E 00 00 01 | – | STAT_L_SONDE_WERT, STAT_L_SONDE_EINH | Lambdasondenspannung Sonde 1 |
STATUS_LS_VKAT_SIGNAL_1 | 12 09 0B 02 0E 00 00 01 | – | STAT_LS_VKAT_SIGNAL_1_WERT, STAT_LS_VKAT_SIGNAL_1_EINH | Lambdasondenspannung Sonde 1 |
STATUS_L_SONDE_2 ¹ | 12 09 0B 02 0E 00 00 02 | – | STAT_L_SONDE_2_WERT, STAT_L_SONDE_2_EINH | Lambdasondenspannung Sonde 2 |
STATUS_LS_VKAT_SIGNAL_2 | 12 09 0B 02 0E 00 00 02 | – | STAT_LS_VKAT_SIGNAL_2_WERT, STAT_LS_VKAT_SIGNAL_2_EINH | Lambdasondenspannung Sonde 2 |
STATUS_MOTORTEMPERATUR_ADC | 12 09 0B 02 0E 00 00 03 | – | STAT_MOTORTEMPERATUR_ADC_WERT, STAT_MOTORTEMPERATUR_ADC_EINH | Motortemperatur ueber ADC-Kanal lesen |
STATUS_ZSI | 12 09 0B 02 0E 00 00 04 | – | STAT_ZSI_WERT, STAT_ZSI_EINH | Lambdasondenspannung Sonde 2 |
STATUS_OEL_TEMPERATUR_ADC | 12 09 0B 02 0E 00 00 05 | – | STAT_OEL_TEMPERATUR_ADC_WERT, STAT_OEL_TEMPERATUR_ADC_EINH | Oeltemperatur ueber ADC-Kanal lesen |
STATUS_LMM_SPANNUNG | 12 09 0B 02 0E 00 00 06 | – | STAT_LMM_SPANNUNG_WERT, STAT_LMM_SPANNUNG_EINH | Spannungssignal Luftmassenmesser (HFM) auslesen |
STATUS_UBATT_ADC | 12 09 0B 02 0E 00 00 07 | – | STAT_UBATT_ADC_WERT, STAT_UBATT_ADC_EINH | Spannungssignal Batterie auslesen |
STATUS_PWG_POTI_SPANNUNG ¹ | 12 09 0B 02 0E 00 00 0812 09 0B 02 0E 00 00 09 | – | STAT_PWG_POTI_SPANNUNG_1_WERT, STAT_PWG_POTI_SPANNUNG_2_WERT, STAT_PWG_POTI_SPANNUNG_EINH, STAT_ROHWERT1 +1 more | Potispannung Pedalwertgeber auslesen |
STATUS_MDK_POTI_SPANNUNG ¹ | 12 09 0B 02 0E 00 00 0A12 09 0B 02 0E 00 00 0B | – | STAT_MDK_POTI_SPANNUNG_1_WERT, STAT_MDK_POTI_SPANNUNG_2_WERT, STAT_MDK_POTI_SPANNUNG_EINH | Potentiometer Motordrosselklappe auslesen |
STATUS_KUEHLW_AUSL_TEMPERATUR_ADC | 12 09 0B 02 0E 00 00 10 | – | STAT_KUEHLW_AUSL_TEMPERATUR_ADC_WERT, STAT_KUEHLW_AUSL_TEMPERATUR_ADC_EINH | Kuehlw_ausl_temperatur ueber ADC-Kanal lesen |
STATUS_KLOPF_ADC1 ¹ | 12 09 0B 02 0E 00 00 17 | – | STAT_KLOPF_ADC1_WERT, STAT_KLOPF_ADC1_EINH | ADC Spannung Klopfsensor 1 |
STATUS_KLOPF_ADC2 ¹ | 12 09 0B 02 0E 00 00 18 | – | STAT_KLOPF_ADC2_WERT, STAT_KLOPF_ADC2_EINH | ADC Spannung Klopfsensor 2 |
STATUS_L_SONDE_H ¹ | 12 09 0B 02 0E 00 00 19 | – | STAT_L_SONDE_H_WERT, STAT_L_SONDE_H_EINH | Lambdasondenspannung Nachkatsonde 1 |
STATUS_LS_NKAT_SIGNAL_1 | 12 09 0B 02 0E 00 00 19 | – | STAT_LS_NKAT_SIGNAL_1_WERT, STAT_LS_NKAT_SIGNAL_1_EINH | Lambdasondenspannung Nachkatsonde 1 |
STATUS_L_SONDE_2_H ¹ | 12 09 0B 02 0E 00 00 1A | – | STAT_L_SONDE_2_H_WERT, STAT_L_SONDE_2_H_EINH | Lambdasondenspannung Nachkatsonde 2 |
STATUS_LS_NKAT_SIGNAL_2 | 12 09 0B 02 0E 00 00 1A | – | STAT_LS_NKAT_SIGNAL_2_WERT, STAT_LS_NKAT_SIGNAL_2_EINH | Lambdasondenspannung Nachkatsonde 2 |
STATUS_MOTORDREHZAHL ¹ | 12 05 0B 03 | – | STAT_MOTORDREHZAHL_WERT, STAT_MOTORDREHZAHL_EINH | Motordrehzahl auslesen |
STATUS_GESCHWINDIGKEIT ¹ | 12 05 0B 03 | – | STAT_GESCHWINDIGKEIT_WERT, STAT_GESCHWINDIGKEIT_EINH | Geschwindigkeit auslesen |
STATUS_PWG_WINKEL ¹ | 12 05 0B 03 | – | STAT_PWG_WINKEL_WERT, STAT_PWG_WINKEL_EINH | |
STATUS_DKP_WINKEL ¹ | 12 05 0B 03 | – | STAT_DKP_WINKEL_WERT, STAT_DKP_WINKEL_ROHWERT1, STAT_DKP_WINKEL_ROHWERT2, STAT_DKP_WINKEL_EINH | Drosselklappenwinkel auslesen |
STATUS_LMM_MASSE ¹ | 12 05 0B 03 | – | STAT_LMM_MASSE_WERT, STAT_LMM_MASSE_EINH | Auslesen Luftmasse kg/h |
STATUS_LMM | 12 05 0B 03 | – | STAT_LMM_WERT, STAT_LMM_EINH | Auslesen Luftmasse kg/h |
STATUS_LL_LUFTBEDARF | 12 05 0B 03 | – | STAT_LL_LUFTBEDARF_WERT, STAT_LL_LUFTBEDARF_EINH | Auslesen Luftmasse kg/h |
STATUS_AN_LUFTTEMPERATUR_MWB | 12 05 0B 03 | – | STAT_AN_LUFTTEMPERATUR_MWB_WERT, STAT_AN_LUFTTEMPERATUR_MWB_EINH | Ansauglufttemperatur auslesen |
STATUS_AN_LUFTTEMPERATUR ¹ | 12 05 0B 03 | – | STAT_AN_LUFTTEMPERATUR_WERT, STAT_AN_LUFTTEMPERATUR_EINH | Ansauglufttemperatur auslesen |
STATUS_MOTORTEMPERATUR_MWB | 12 05 0B 03 | – | STAT_MOTORTEMPERATUR_MWB_WERT, STAT_MOTORTEMPERATUR_MWB_EINH | Motortemperatur auslesen ueber MWB |
STATUS_MOTORTEMPERATUR ¹ | 12 05 0B 03 | – | STAT_MOTORTEMPERATUR_WERT, STAT_MOTORTEMPERATUR_EINH | Motortemperatur auslesen |
STATUS_OEL_TEMPERATUR_MWB | 12 05 0B 03 | – | STAT_OEL_TEMPERATUR_MWB_WERT, STAT_OEL_TEMPERATUR_MWB_EINH | Oeltemperatur auslesen |
STATUS_OEL_TEMPERATUR ¹ | 12 05 0B 03 | – | STAT_OEL_TEMPERATUR_WERT, STAT_OEL_TEMPERATUR_EINH | Oeltemperatur auslesen |
STATUS_KUEHLW_AUSL_TEMPERATUR_MWB | 12 04 0012 09 06 00 04 03 F0 xx12 05 0B 03 | – | STAT_KUEHLW_AUSL_TEMPERATUR_MWB_WERT, STAT_KUEHLW_AUSL_TEMPERATUR_MWB_EINH | Kuehlwasserauslasstemperatur auslesen |
STATUS_KUEHLW_AUSL_TEMPERATUR ¹ | 12 04 0012 09 06 00 04 03 F0 xx12 05 0B 03 | – | STAT_KUEHLW_AUSL_TEMPERATUR_WERT, STAT_KUEHLW_AUSL_TEMPERATUR_EINH | Kuehlwasserauslasstemperatur auslesen |
STATUS_ZUENDWINKEL ¹ | 12 05 0B 03 | – | STAT_ZUENDWINKEL_WERT, STAT_ZUENDWINKEL_EINH | Zuendwinkel auslesen |
STATUS_EINSPRITZZEIT ¹ | 12 05 0B 03 | – | STAT_EINSPRITZZEIT_WERT, STAT_EINSPRITZZEIT_EINH | Auslesen der Einspritzzeit pro Umdrehung |
STATUS_LL_INTEGRATOR ¹ | 12 05 0B 03 | – | STAT_LL_INTEGRATOR_WERT, STAT_LL_INTEGRATOR_EINH | Auslesen des Leerlaufintegrators |
STATUS_LL_STELLER_TV ¹ | 12 05 0B 03 | – | STAT_LL_STELLER_TV_WERT, STAT_LL_STELLER_TV_EINH | Tastverhaeltnis Ansteuerung LL-Steller auslesen |
STATUS_VANOS_NW_LAGE_EINLASS ¹ | 12 05 0B 03 | – | STAT_VANOS_NW_LAGE_EINLASS_IST_WERT, STAT_VANOS_NW_LAGE_EINLASS_EINH | Auslesen Einlassvanos Istlage |
STATUS_VANOS_NW_LAGE_AUSLASS ¹ | 12 05 0B 03 | – | STAT_VANOS_NW_LAGE_AUSLASS_IST_WERT, STAT_VANOS_NW_LAGE_AUSLASS_EINH | Auslesen AUSlassvanos Istlage |
STATUS_KL15 | 12 05 0B 03 | – | STAT_KL15_WERT, STAT_KL15_EINH | Batteriespannung KL15 auslesen |
STATUS_LAMBDA_INTEGRATOR_1 | 12 05 0B 03 | – | STAT_LAMBDA_INTEGRATOR_1_WERT, STAT_LAMBDA_INTEGRATOR_1_EINH | Lambdaregler BANK 1 auslesen |
STATUS_INT ¹ | 12 05 0B 03 | – | STAT_INT_WERT, STAT_INT_EINH | Lambdaregler BANK 1 auslesen |
STATUS_LAMBDA_INTEGRATOR_2 | 12 05 0B 03 | – | STAT_LAMBDA_INTEGRATOR_2_WERT, STAT_LAMBDA_INTEGRATOR_2_EINH | Lambdaregelfaktor Bank 2 auslesen |
STATUS_INT_2 ¹ | 12 05 0B 03 | – | STAT_INT_2_WERT, STAT_INT_2_EINH | Lambdaregelfaktor Bank 2 auslesen |
STATUS_LS_VKAT_HEIZUNG_TV_1 ¹ | 12 05 0B 03 | – | STAT_LS_VKAT_HEIZUNG_TV_1_WERT, STAT_LS_VKAT_HEIZUNG_TV_1_EINH | Tastverhaeltnis Ansteuerung Lambdasondenheizung VKAT Bank 1 auslesen |
STATUS_LS_VKAT_HEIZUNG_TV_2 ¹ | 12 05 0B 03 | – | STAT_LS_VKAT_HEIZUNG_TV_2_WERT, STAT_LS_VKAT_HEIZUNG_TV_2_EINH | Tastverhaeltnis Ansteuerung Lambdasondenheizung VKAT Bank 2 auslesen |
STATUS_LS_NKAT_HEIZUNG_TV_1 ¹ | 12 05 0B 03 | – | STAT_LS_NKAT_HEIZUNG_TV_1_WERT, STAT_LS_NKAT_HEIZUNG_TV_1_EINH | Tastverhaeltnis Ansteuerung Lambdasondenheizung NKAT Bank 1 auslesen |
STATUS_LS_NKAT_HEIZUNG_TV_2 ¹ | 12 05 0B 03 | – | STAT_LS_NKAT_HEIZUNG_TV_2_WERT, STAT_LS_NKAT_HEIZUNG_TV_2_EINH | Tastverhaeltnis Ansteuerung Lambdasondenheizung NKAT Bank 2 auslesen |
STATUS_LAST | 12 05 0B 03 | – | STAT_LAST_WERT, STAT_LAST_EINH | Last mg/Hub auslesen |
STATUS_K_MW_2 | 12 05 0B 03 | – | STAT_K_MW_2_WERT, STAT_K_MW_2_EINH | Wert Ubat auslesen |
STATUS_K_MW_5 | 12 05 0B 03 | – | STAT_K_MW_5_WERT, STAT_K_MW_5_EINH | Wert Ubat auslesen |
STATUS_DREHZAHL_E_LUEFTER_VON_AC | 12 05 0B 03 | – | STAT_DREHZAHL_E_LUEFTER_VON_AC_WERT, STAT_DREHZAHL_E_LUEFTER_VON_AC_EINH | Auslesen der Drehzahlstufe E-Luefter, Anforderung durch Klimaanlage, 1-15 |
STATUS_LUFTDRUCK | 12 05 0B 03 | – | STAT_LUFTDRUCK_WERT, STAT_LUFTDRUCK_EINH | Auslesen des Luftdrucks |
STATUS_UBATT ¹ | 12 05 0B 03 | – | STAT_UBATT_WERT, STAT_UBATT_EINH | Batteriespannung nach HR auslesen |
STATUS_MESSWERTEBLOCK | 12 05 0B 03 | – | STAT_MOTORDREHZAHL_MWB_WERT, STAT_MOTORDREHZAHL_MWB_EINH, STAT_GESCHWINDIGKEIT_MWB_WERT, STAT_GESCHWINDIGKEIT_MWB_EINH +52 more | Messwerteblock auslesen |
STATUS_DIGITAL ¹ | 12 05 0B 04 | – | STAT_KO_EIN, STAT_AC_EIN, STAT_FGR_EIN, STAT_KUP_EIN +43 more | Status Schalteingaenge |
STATUS_FGR_ABSCHALTUNG | 12 05 0B 05 | – | STAT_ENDSTUFE_DK, STAT_TIMEOUT_ASC, STAT_VS_SIGNAL, STAT_TPS_FEHLER +22 more | Status Abschaltbedingungen FGR |
STATUS_VANOS_NW_LAGE_IST_SOLL_REF_EINLASS ¹ | 12 05 0B 90 | – | STAT_VANOS_NW_LAGE_EINLASS_IST_WERT, STAT_VANOS_NW_LAGE_EINLASS_SOLL_WERT, STAT_VANOS_NW_LAGE_EINLASS_REF_WERT, STAT_VANOS_NW_LAGE_IST_SOLL_REF_EINLASS_EINH | Auslesen Einlassvanos Ist-, Soll-, Ref-lage |
STATUS_VANOS_NW_FLANKENADAPTION ¹ | 12 05 0B 90 | – | STAT_VANOS_NW_FLANKENADAPTION_EINLASS_WERT, STAT_VANOS_NW_FLANKENADAPTION_AUSLASS_WERT, STAT_VANOS_NW_FLANKENADAPTION_EINH | Auslesen VANOS Nockenwellen-Flankenadaption |
STATUS_VANOS_NW_ROHWERT | 12 05 0B 90 | – | STAT_VANOS_NW_ROHWERT_EINLASS_WERT, STAT_VANOS_NW_ROHWERT_AUSLASS_WERT, STAT_VANOS_NW_ROHWERT_EINH | Auslesen VANOS Nockenwellen-Rohwert |
STATUS_VANOS_NW_LAGE_IST_SOLL_REF_AUSLASS ¹ | 12 05 0B 90 | – | STAT_VANOS_NW_LAGE_AUSLASS_IST_WERT, STAT_VANOS_NW_LAGE_AUSLASS_SOLL_WERT, STAT_VANOS_NW_LAGE_AUSLASS_REF_WERT, STAT_VANOS_NW_LAGE_IST_SOLL_REF_AUSLASS_EINH | Auslesen Auslassvanos Ist-, Soll-, Ref-lage |
STATUS_ADD | 12 05 0B 91 | – | STAT_ADD_WERT, STAT_ADD_EINH | Adaption Gemisch additiv auslesen Bank1 |
STATUS_LAMBDA_ADD_1 ¹ | 12 05 0B 91 | – | STAT_LAMBDA_ADD_1_WERT, STAT_LAMBDA_ADD_1_EINH | Adaption Gemisch additiv auslesen Bank1 |
STATUS_MUL | 12 05 0B 91 | – | STAT_MUL_WERT, STAT_MUL_EINH | Adaption Gemisch multiplikativ auslesen Bank1 |
STATUS_LAMBDA_MUL_1 ¹ | 12 05 0B 91 | – | STAT_LAMBDA_MUL_1_WERT, STAT_LAMBDA_MUL_1_EINH | Adaption Gemisch multiplikativ auslesen Bank1 |
STATUS_ADD_2 | 12 05 0B 91 | – | STAT_ADD_2_WERT, STAT_ADD_2_EINH | Adaption Gemisch additiv auslesen Bank2 |
STATUS_LAMBDA_ADD_2 ¹ | 12 05 0B 91 | – | STAT_LAMBDA_ADD_2_WERT, STAT_LAMBDA_ADD_2_EINH | Adaption Gemisch additiv auslesen Bank2 |
STATUS_MUL_2 | 12 05 0B 91 | – | STAT_MUL_2_WERT, STAT_MUL_2_EINH | Adaption Gemisch multiplikativ auslesen Bank2 |
STATUS_LAMBDA_MUL_2 ¹ | 12 05 0B 91 | – | STAT_LAMBDA_MUL_2_WERT, STAT_LAMBDA_MUL_2_EINH | Adaption Gemisch multiplikativ auslesen Bank2 |
STATUS_ADAP_AKTIV | 12 05 0B 91 | – | STAT_ADAP_B1_AKTIV_WERT, STAT_ADAP_B2_AKTIV_WERT | Adaption Gemisch multiplikativ auslesen Bank2 |
STATUS_LL_ADAPTION | 12 05 0B 92 | – | STAT_LL_ADAPTION_WERT, STAT_LL_ADAPTION_EINH | LL-Adaption ohne FS auslesen |
STATUS_LL_FS_ADAPTION | 12 05 0B 92 | – | STAT_LL_FS_ADAPTION_WERT, STAT_LL_FS_ADAPTION_EINH | LL-Adaption mit FS auslesen |
STATUS_LL_KK_ADAPTION | 12 05 0B 92 | – | STAT_LL_KK_ADAPTION_WERT, STAT_LL_KK_ADAPTION_EINH | LL-Adaption mit KK auslesen |
STATUS_PWG1_WINKEL ¹ | 12 05 0B 92 | – | STAT_PWG1_WINKEL_WERT, STAT_PWG1_WINKEL_EINH | |
STATUS_PWG2_WINKEL | 12 05 0B 92 | – | STAT_PWG2_WINKEL_WERT, STAT_PWG2_WINKEL_EINH | |
STATUS_DK1_WINKEL | 12 05 0B 92 | – | STAT_DK1_WINKEL_WERT, STAT_DK1_WINKEL_EINH | |
STATUS_DK2_WINKEL | 12 05 0B 92 | – | STAT_DK2_WINKEL_WERT, STAT_DK2_WINKEL_EINH | |
STATUS_DK_ADAP_UMA_MECH | 12 05 0B 92 | – | STAT_DK_ADAP_UMA_MECH1_WERT, STAT_DK_ADAP_UMA_MECH1_EINH, STAT_DK_ADAP_UMA_MECH2_WERT, STAT_DK_ADAP_UMA_MECH2_EINH | |
STATUS_DK_ADAP_UMA_EL | 12 05 0B 92 | – | STAT_DK_ADAP_UMA_EL1_WERT, STAT_DK_ADAP_UMA_EL1_EINH, STAT_DK_ADAP_UMA_EL2_WERT, STAT_DK_ADAP_UMA_EL2_EINH | |
STATUS_DK_ADAP_LIH | 12 05 0B 92 | – | STAT_DK_ADAP_LIH1_WERT, STAT_DK_ADAP_LIH1_EINH, STAT_DK_ADAP_LIH2_WERT, STAT_DK_ADAP_LIH2_EINH | |
STATUS_DK_ADAP_BEDARF | 12 05 0B 92 | – | STAT_DK_ADAP_BEDARF_TEXT | Bit Drosselklappenadaptionsbedarf auslesen |
STATUS_KR | 12 05 0B 93 | – | STAT_KR_ADAP_WERT, STAT_KR_ADAP_EINH | KR_Aadaption auslesen |
STATUS_FREIGABEZAEHLER_DMTL | 12 05 0B 97 | – | STAT_FREIGABEZAEHLER_DMTL_WERT | Freigabezaehler DMTL auslesen |
STATUS_MESS_ABBRUCH_DMTL | 12 05 0B 97 | – | STAT_MESS_ABBRUCH_DMTL_WERT | Anzahl der abgebr. Messungen wegen delta I auslesen |
STATUS_GROBLECKMESSUNG_DMTL | 12 05 0B 97 | – | STAT_GROBLECKMESSUNG_DMTL_WERT | Anzahl der durchgefuehrten Grobleckmessungen auslesen |
STATUS_FEINLECKMESSUNG_DMTL | 12 05 0B 97 | – | STAT_FEINLECKMESSUNG_DMTL_WERT | Anzahl der durchgefuehrten Feinleckmessungen auslesen |
STATUS_DMTL_EOL ¹ | 12 05 0B 97 | – | STAT_DMTL_EOL_WERT, STAT_SYSTEMCHECK_STATE_DMTL_TEXT | Status Fkt.-Test Tankleckage mittels DMTL auslesen |
STATUS_FUSSHEBELFEHLBETAETIGUNG | 12 05 0B 98 | – | STAT_FUSSHEBELFEHLBETAETIGUNG_WERT, STAT_FUSSHEBELFEHLBETAETIGUNG_KM_MAX_WERT, STAT_FUSSHEBELFEHLBETAETIGUNG_KM_MAX_EINH | Fusshebelfehlbedienung auslesen |
STATUS_DIAGNOSEWERTE_KAT_LS_SEK | 12 05 0B 99 | – | STAT_DIAGNOSEWERTE_KAT_BANK1_WERT, STAT_DIAGNOSEWERTE_KAT_BANK2_WERT, STAT_DIAGNOSEWERTE_REGELFREQUENZ_FETT_B1_WERT, STAT_DIAGNOSEWERTE_REGELFREQUENZ_FETT_B2_WERT +7 more | Diagnosewerte Kat, LS, SEK auslesen |
STATUS_DIGITAL_OBDII | 12 05 0B A3 | – | STAT_MIL, ANZAHL_MIL, STAT_UBW_KOMP, STAT_UBW_KVS +13 more | Status Readiness |
STATUS_KM_MIL | 12 05 0B A3 | – | STAT_KM_MIL_WERT, STAT_KM_MIL_EINH | Kilometer seit MIL auslesen |
STATUS_GEBERRAD_ADAPTION | 12 05 0B 04 | – | STAT_GEBERRAD_ADAPTION_WERT, STAT_GEBERRAD_ADAPTION_EINH | Geberradadaption |
System checks (37)
| Job | Request | Arguments | Results | SGBD comment |
|---|---|---|---|---|
STATUS_SYSTEMCHECK_TEV | 12 05 2B 01 | – | STAT_SYSTEMCHECK_TEV, STAT_SYSTEMCHECK_TEV_ANZ_FKT_CHECKS_WERT, STAT_SYSTEMCHECK_TEV_ANZ_TV_FKT_CHECKS_WERT | Systemcheck Tankentlueftungssystem Leckdiagnose lesen |
STATUS_SYSTEMCHECK_SEK_LUFT_SAF | 12 05 2B 02 | – | STAT_SYSTEMCHECK_SEK_LUFT_SAF_DIAG_MAX_WERT, STAT_SYSTEMCHECK_SEK_LUFT_SAF_DIAG_MAX_EINH, STAT_SYSTEMCHECK_SEK_LUFT_SAF_DIAG_MIN_WERT, STAT_SYSTEMCHECK_SEK_LUFT_SAF_DIAG_MIN_EINH +1 more | Systemcheck Sekundaerluft lesen mit SAF |
STATUS_SYSTEMCHECK_SEK_LUFT | 12 05 2B 02 | – | STAT_SYSTEMCHECK_SEK_LUFT_BANK_1_WERT, STAT_SYSTEMCHECK_SEK_LUFT_BANK_2_WERT, STAT_SYSTEMCHECK_SEK_LUFT_FLAG_WERT | Systemcheck Sekundaerluft lesen mit SAF |
LESEN_SYSTEMCHECK_SEK_LUFT ¹ | 12 05 2B 02 | – | LESEN_SYSTEMCHECK_SEK_LUFT_BANK_1_WERT, LESEN_SYSTEMCHECK_SEK_LUFT_BANK_2_WERT, LESEN_SYSTEMCHECK_SEK_LUFT_FLAG | Systemcheck Sekundaerluft lesen |
STATUS_SYSTEMCHECK_DMTL ¹ | 12 04 0012 05 2B 03 | – | STAT_SYSTEMCHECK_STATE_DMTL_TEXT, STAT_SYSTEMCHECK_REF_STROM_DMTL_WERT, STAT_SYSTEMCHECK_REF_STROM_DMTL_EINH, STAT_SYSTEMCHECK_GROB_STROM_DMTL_WERT +3 more | Systemcheck Leckdiagnose mittels DMTL |
LESEN_SYSTEMCHECK_TANK_LECK | 12 04 0012 05 2B 03 | – | LESEN_SYSTEMCHECK_DMTL_STATUS, LESEN_SYSTEMCHECK_TANK_LECK_STATUS, LESEN_SYSTEMCHECK_TANK_LECK_AKTIV_WERT, LESEN_SYSTEMCHECK_TANK_LECK_PER_WERT +1 more | Ergebnis Funktionsueberpruefung DMTL abrufen |
LESEN_SYSTEMCHECK_DMTL | 12 04 0012 05 2B 03 | – | LESEN_SYSTEMCHECK_DMTL_TEXT, LESEN_SYSTEMCHECK_DMTL_STATUS, LESEN_SYSTEMCHECK_DMTL_WERT, LESEN_SYSTEMCHECK_DMTL_AKTIV_WERT | Ergebnis Funktionsueberpruefung DMTL abrufen |
STATUS_SYSTEMCHECK_SONDENHEIZUNG ¹ | 12 05 2B 04 | – | STAT_SYSTEMCHECK_SONDENHEIZUNG, STAT_SYSTEMCHECK_SONDENHEIZUNG_ULS_MIN_BANK1_WERT, STAT_SYSTEMCHECK_SONDENHEIZUNG_ULS_MAX_BANK1_WERT, STAT_SYSTEMCHECK_SONDENHEIZUNG_ULS_MIN_BANK2_WERT +7 more | Systemcheck Lambdasondenheizung lesen |
STATUS_SYSTEMCHECK_LAUFUNRUHE ¹ | 12 05 2B 05 | – | STAT_SYSTEMCHECK_LAUFUNRUHE, STAT_SYSTEMCHECK_LAUFUNRUHE_ZYL1_WERT, STAT_SYSTEMCHECK_LAUFUNRUHE_ZYL5_WERT, STAT_SYSTEMCHECK_LAUFUNRUHE_ZYL3_WERT +9 more | Systemcheck Laufunruhe lesen |
LESEN_SYSTEMCHECK_LAUFUNRUHE | 12 05 2B 05 | – | LESEN_SYSTEMCHECK_LAUFUNRUHE_ZYL1_WERT, LESEN_SYSTEMCHECK_LAUFUNRUHE_ZYL2_WERT, LESEN_SYSTEMCHECK_LAUFUNRUHE_ZYL3_WERT, LESEN_SYSTEMCHECK_LAUFUNRUHE_ZYL4_WERT +2 more | Laufunruhe lesen |
STATUS_SYSTEMCHECK_VERTAUSCHT_LAMBDASONDEN | 12 05 2B 06 | – | STAT_SYSTEMCHECK_VERTAUSCHT_LAMBDASONDEN, STAT_SYSTEMCHECK_VERTAUSCHT_LAMBDASONDEN_DIAG, STAT_SYSTEMCHECK_VERTAUSCHT_LAMBDASONDEN_DIAG_TEXT, STAT_SYSTEMCHECK_URLS_FETT_BANK1_WERT +10 more | Systemcheck fuer vertauschte Lambdasonden f. Bandende und Werkstatt lesen |
STATUS_SYSTEMCHECK_SEK_LUFT_PUMPE | 12 05 2B 81 | – | STAT_SYSTEMCHECK_SEK_LUFT_MASSE_WERT, STAT_SYSTEMCHECK_SEK_LUFT_MASSE_EINH | Systemcheck Sekundaerluft lesen |
STATUS_SYSTEMCHECK_KENNFELDTHERMOSTAT | 12 05 2B 8312 05 0B 03 | – | STAT_SYSTEMCHECK_KENNFELDTHERMOSTAT_TCO_WERT, STAT_SYSTEMCHECK_KENNFELDTHERMOSTAT_TCO_EINH, STAT_SYSTEMCHECK_KENNFELDTHERMOSTAT_WERT, STAT_SYSTEMCHECK_KENNFELDTHERMOSTAT_EINH | Systemcheck Kennfeldthermostat lesen |
STATUS_SYSTEMCHECK_DMTL_MOTOR | 12 05 2B 8612 05 2B 03 | – | STAT_SYSTEMCHECK_DMTL_MOTOR_WERT, STAT_SYSTEMCHECK_DMTL_MOTOR_EINH | Systemcheck DMTL lesen |
STATUS_SYSTEMCHECK_DK_WINKEL | 12 05 2B 95 | – | STAT_SYSTEMCHECK_DK_WINKEL_WERT, STAT_SYSTEMCHECK_DK_WINKEL_EINH | Systemcheck Drosselklappenwinkel lesen |
STATUS_SYSTEMCHECK_LSH_VKAT_BANK1 | 12 05 2B 9A12 05 2B 04 | – | STAT_SYSTEMCHECK_LSH_VKAT_BANK1_WERT, STAT_SYSTEMCHECK_LSH_VKAT_BANK1_EINH | Systemcheck LSH VKAT Bank1 |
STATUS_SYSTEMCHECK_LSH_VKAT_BANK2 | 12 05 2B 9B12 05 2B 04 | – | STAT_SYSTEMCHECK_LSH_VKAT_BANK2_WERT, STAT_SYSTEMCHECK_LSH_VKAT_BANK2_EINH | Systemcheck LSH VKAT Bank2 |
STATUS_SYSTEMCHECK_LSH_NKAT_BANK1 | 12 05 2B 9C12 05 2B 04 | – | STAT_SYSTEMCHECK_LSH_NKAT_BANK1_WERT, STAT_SYSTEMCHECK_LSH_NKAT_BANK1_EINH | Systemcheck LSH NKAT Bank1 |
STATUS_SYSTEMCHECK_LSH_NKAT_BANK2 | 12 05 2B 9D12 05 2B 04 | – | STAT_SYSTEMCHECK_LSH_NKAT_BANK2_WERT, STAT_SYSTEMCHECK_LSH_NKAT_BANK2_EINH | Systemcheck LSH NKAT Bank2 |
STATUS_VERSTELLZEIT_MESS_VANOS_E ¹ | 12 05 2B A0 | – | STAT_VERSTELLZEIT_MESS_VANOS_E_STAT, STAT_VERSTELLZEIT_MESS_VANOS_E_TEXT, STAT_VERSTELLZEIT_MESS_VANOS_E_FR_WERT, STAT_VERSTELLZEIT_MESS_VANOS_E_SP_WERT +1 more | Verstellzeitmessung Nockenwelle Einlass |
STATUS_VERSTELLZEIT_MESS_VANOS_A ¹ | 12 05 2B A1 | – | STAT_VERSTELLZEIT_MESS_VANOS_A_STAT, STAT_VERSTELLZEIT_MESS_VANOS_A_TEXT, STAT_VERSTELLZEIT_MESS_VANOS_A_FR_WERT, STAT_VERSTELLZEIT_MESS_VANOS_A_SP_WERT +1 more | Verstellzeitmessung Nockenwelle Auslass |
STATUS_DICHTHEIT_MESS_VANOS_E ¹ | 12 05 2B A2 | – | STAT_DICHTHEIT_MESS_VANOS_E_STAT, STAT_DICHTHEIT_MESS_VANOS_E_DELTA_WERT, STAT_DICHTHEIT_MESS_VANOS_E_EINH | Dichtheitsmessung Nockenwelle Einlass |
STATUS_DICHTHEIT_MESS_VANOS_A ¹ | 12 05 2B A3 | – | STAT_DICHTHEIT_MESS_VANOS_A_STAT, STAT_DICHTHEIT_MESS_VANOS_A_DELTA_WERT, STAT_DICHTHEIT_MESS_VANOS_A_EINH | Dichtheitsmessung Nockenwelle Auslass |
STATUS_SYSTEMCHECK_NWG_IST_EINLASS | 12 05 2B A412 05 0B 03 | – | STAT_SYSTEMCHECK_NWG_IST_EINLASS_WERT, STAT_SYSTEMCHECK_NWG_IST_EINLASS_EINH | Systemcheck Istwert Nockenwellengeber Einlass |
STATUS_SYSTEMCHECK_NWG_IST_AUSLASS | 12 05 2B A512 05 0B 03 | – | STAT_SYSTEMCHECK_NWG_IST_AUSLASS_WERT, STAT_SYSTEMCHECK_NWG_IST_AUSLASS_EINH | Systemcheck Istwert Nockenwellengeber Auslass |
STATUS_SYSTEMCHECK_SEK_LUFT_VENTIL | 12 05 2B BA12 05 2B 81 | – | STAT_SYSTEMCHECK_SEK_LUFTMASSE_WERT, STAT_SYSTEMCHECK_SEK_LUFTMASSE_EINH | Systemcheck Sekundaerluftventil lesen |
START_SYSTEMCHECK_TEV_FUNC ¹ | 12 05 22 01 | – | START_SYSTEMCHECK_TEV_FUNC_STATUS | Systemcheck TEV Functionalcheck starten |
LESEN_SYSTEMCHECK_TEV_FUNC ¹ | 12 05 2B 01 | – | LESEN_SYSTEMCHECK_TEV_WERT, STAT_SYSTEMCHECK_TEV, STAT_SYSTEMCHECK_TEV_ANZ_FKT_CHECKS_WERT, STAT_SYSTEMCHECK_TEV_ANZ_TV_FKT_CHECKS_WERT | Systemcheck Tankentlueftungssystem Leckdiagnose lesen |
START_SYSTEMCHECK_SEK_LUFT ¹ | 12 05 22 02 | – | START_SYSTEMCHECK_SEK_LUFT_STATUS | Systemcheck Sekundaerluft starten |
STOP_SYSTEMCHECK_SEK_LUFT ¹ | 12 05 23 02 | – | – | Systemcheck Sekundaerluft stoppen |
START_SYSTEMCHECK_TANK_LECK ¹ | 12 05 22 03 | – | START_SYSTEMCHECK_TANK_LECK_STATUS, START_SYSTEMCHECK_DMTL_STATUS | Systemcheck Tankentlueftungssystem Leckdiagnose starten |
TEST_SYSTEMCHECK_DMTL | 12 05 22 03 | – | TEST_SYSTEMCHECK_DMTL_STATUS | Systemcheck Tankentlueftungssystem Leckdiagnose starten |
START_SYSTEMCHECK_DMTL | 12 05 22 03 | – | START_SYSTEMCHECK_DMTL_STATUS | Systemcheck Tankentlueftungssystem Leckdiagnose starten |
START_SYSTEMCHECK_DMTL_ECOS | 12 04 0012 05 23 0312 06 41 0A xx12 04 9F12 05 22 0312 05 2B 03 | – | STAT_SYSTEMCHECK_DMTL, STAT_DMTL_ECOS | Systemcheck Tankentlueftungssystem Leckdiagnose starten |
START_SYSTEMCHECK_SONDENHEIZUNG ¹ | 12 05 22 04 | – | START_SYSTEMCHECK_SONDENHEIZUNG_STATUS | Systemcheck Lambdasondenheizung starten |
START_SYSTEMCHECK_LAUFUNRUHE | 12 05 22 05 | – | START_SYSTEMCHECK_LAUFUNRUHE_STATUS | Systemcheck Laufunruhe starten |
START_SYSTEMCHECK_VERTAUSCHT_LAMBDASONDEN | 12 05 22 06 | – | START_SYSTEMCHECK_VERTAUSCHT_LAMBDASONDEN_STATUS | Systemcheck vertauschte Lambdasonden |
Actuator tests (STEUERN_*) (51)
| Job | Request | Arguments | Results | SGBD comment |
|---|---|---|---|---|
STEUERN_SEK_PUMPE ¹ | 12 06 22 81 xx | PUMPE_EIN_AUS | – | Sekundaerluftpumpe ansteuern |
STEUERN_EV_SELEKTIV_AUSBLENDEN | 12 06 22 82 xx | ZYLINDER_AUSWAHL | – | EV selektiv ausblenden, Zylinder 1- 6 angeben |
STEUERN_EV_1_AUS | 12 06 22 82 01 | – | – | EV 1 ausschalten |
STEUERN_EV_2_AUS | 12 06 22 82 02 | – | – | EV 2 ausschalten |
STEUERN_EV_3_AUS | 12 06 22 82 04 | – | – | EV 3 ausschalten |
STEUERN_EV_4_AUS | 12 06 22 82 08 | – | – | EV 4 ausschalten |
STEUERN_EV_5_AUS | 12 06 22 82 10 | – | – | EV 5 ausschalten |
STEUERN_EV_6_AUS | 12 06 22 82 20 | – | – | EV 1 ausschalten |
STEUERN_KF_THERMOSTAT ¹ | 12 06 22 83 xx | TASTVERHAELTNIS | – | Kennfeldthermostat verstellen : Default= 80 % |
STEUERN_EKP ¹ | 12 06 22 84 xx | PUMPE_EIN_AUS | – | EKP-Relais ansteuern: Default Ein=0xFF , Aus=0x00 |
STEUERN_DMTL_MOTOR | 12 06 22 86 xx | MOTOR_EIN_AUS | – | DMTL-Motor ansteuern |
STEUERN_DMTL_VENTIL | 12 06 22 87 xx | VENTIL_AUF_ZU | – | DMTL-Ventil ansteuern |
STEUERN_DISA ¹ | 12 06 22 88 xx | DISA_EIN_AUS | – | Disa ansteuern : 0x00 = DISA Aus : 0xFF = DISA Ein |
STEUERN_DMTL_HEIZUNG | 12 06 22 8B 0012 06 22 8B FF | SCHALTEN | – | Stellgliedansteuerung DMTL-Heizung |
STEUERN_ABGASKLAPPE ¹ | 12 06 22 8A xx | AKL_AUF_ZU | – | Abgasklappe ansteuern , 0x00 AKL = Zu , 0xFF AKL = Auf |
STEUERN_E_LUEFTER ¹ | 12 06 22 8E xx | TASTVERHAELTNIS | – | E-Luefter verstellen |
STEUERN_E_LUEFTER_ECOS | 12 04 0012 06 22 8E xx | – | – | E-Luefter verstellen |
STEUERN_LL_DREHZAHL_VERSTELLEN ¹ | 12 06 22 90 xx | DREHZAHL | – | LL-Drehzahl verstellen, 512-1792 U/min |
STEUERN_MIL ¹ | 12 06 22 91 xx | MIL_EIN_AUS | – | Fehlerlampe MIL ansteuern : 0x00 MIL Aus : 0xFF MIL = Ein |
STEUERN_TEMP_ANZEIGE_KOMBI ¹ | 12 07 22 92 xx xx | TEMPERATUR, UEBERTEMP_EIN_AUS | – | Temperaturanzeige Kombi verstellen |
STEUERN_KO ¹ | 12 06 22 94 xx | KOMPRESSOR_EIN_AUS | – | Klimakompressorrelais ansteuern : Ein=0xff , Aus=0x00 |
STEUERN_DK_WINKEL ¹ | 12 07 22 95 xx xx | WINKELVORGABE | – | DK-Winkel verstellen |
STEUERN_LS_HEIZUNG_VKAT_BANK1 | 12 06 22 9A xx | TASTVERHAELTNIS | – | Lambdasondenheizung verstellen, 0 - 99 % |
STEUERN_LS_HEIZUNG_VKAT_BANK2 | 12 06 22 9B xx | TASTVERHAELTNIS | – | Lambdasondenheizung verstellen, 0 - 99 % |
STEUERN_LS_HEIZUNG_NKAT_BANK1 | 12 06 22 9C xx | TASTVERHAELTNIS | – | Lambdasondenheizung verstellen, 0 - 99 % |
STEUERN_LS_HEIZUNG_NKAT_BANK2 | 12 06 22 9D xx | TASTVERHAELTNIS | – | Lambdasondenheizung verstellen, 0 - 99 % |
STEUERN_VANOS_E_VERSTELLZEIT ¹ | 12 07 22 A0 xx xx12 05 0B 90 | POS1, POS2 | – | Verstellzeitmessung VANOS-E |
STEUERN_VANOS_A_VERSTELLZEIT ¹ | 12 07 22 A1 xx xx12 05 0B 90 | POS1, POS2 | – | Verstellzeitmessung VANOS-A |
STEUERN_VANOS_E_DICHTHEIT ¹ | 12 07 22 A2 xx xx12 05 0B 90 | POS, TIME | – | Messung Dichtheit VANOS-Einlass |
STEUERN_VANOS_A_DICHTHEIT ¹ | 12 07 22 A3 xx xx12 05 0B 90 | POS, TIME | – | Messung Dichtheit VANOS-Auslass |
STEUERN_VANOS_E_SOLLWERT ¹ | 12 06 22 A4 xx12 05 0B 90 | NW_SPREIZUNG | – | Sollwert Vanos E vorgeben |
STEUERN_VANOS_A_SOLLWERT ¹ | 12 06 22 A5 xx12 05 0B 90 | NW_SPREIZUNG | – | Sollwert Vanos A vorgeben |
STEUERN_VANOS_E_VENTIL ¹ | 12 06 22 A6 xx | TASTVERHAELTNIS | – | Vanos E-Ventil ansteuern |
STEUERN_VANOS_A_VENTIL ¹ | 12 06 22 A7 xx | TASTVERHAELTNIS | – | Vanos A-Ventil ansteuern |
STEUERN_EV_1_ARG | 12 07 22 B1 xx xx | ANSTEUERZEIT, PERIODENDAUER | – | EV 1 ansteuern |
STEUERN_EV_2_ARG | 12 07 22 B2 xx xx | ANSTEUERZEIT, PERIODENDAUER | – | EV 2 ansteuern |
STEUERN_EV_3_ARG | 12 07 22 B3 xx xx | ANSTEUERZEIT, PERIODENDAUER | – | EV 3 ansteuern |
STEUERN_EV_4_ARG | 12 07 22 B4 xx xx | ANSTEUERZEIT, PERIODENDAUER | – | EV 4 ansteuern |
STEUERN_EV_5_ARG | 12 07 22 B5 xx xx | ANSTEUERZEIT, PERIODENDAUER | – | EV 5 ansteuern |
STEUERN_EV_6_ARG | 12 07 22 B6 xx xx | ANSTEUERZEIT, PERIODENDAUER | – | EV 6 ansteuern |
STEUERN_EV_1 ¹ | 12 07 22 B1 5D 0A | – | – | EV 1 ansteuern |
STEUERN_EV_2 ¹ | 12 07 22 B2 5D 0A | – | – | EV 2 ansteuern |
STEUERN_EV_3 ¹ | 12 07 22 B3 5D 0A | – | – | EV 3 ansteuern |
STEUERN_EV_4 ¹ | 12 07 22 B4 5D 0A | – | – | EV 4 ansteuern |
STEUERN_EV_5 ¹ | 12 07 22 B5 5D 0A | – | – | EV 5 ansteuern |
STEUERN_EV_6 ¹ | 12 07 22 B6 5D 0A | – | – | EV 6 ansteuern |
STEUERN_LL_STELLER ¹ | 12 06 22 B7 xx | TASTVERHAELTNIS | – | Leerlaufsteller ansteuern , 5-94% |
STEUERN_SEK_VENTIL ¹ | 12 06 22 BA xx | VENTIL_AUF_ZU | – | Sekundaerluftventil ansteuern, 0=inaktiv , 0xFF=aktiv |
STEUERN_TEV ¹ | 12 06 22 BB xx | TASTVERHAELTNIS | – | Tankentlueftungsventil ansteuern |
STEUERN_DMTL_TEV | 12 06 22 BB xx12 06 22 87 xx12 06 22 86 xx | TASTVERHAELTNIS | – | TEV-, DMTL-Ventil u. DMTL-Motor ansteuern |
STEUERN_LL_MANIPULATION | 12 06 22 90 xx12 05 0B 03 | DREHZAHL | STAT_LL_MANIPULATION_WERT, STAT_LL_MANIPULATION_EINH | LL-Drehzahl verstellen (512 bis 1792 U/min) und danach einlesen |
Trim adjustments (10)
| Job | Request | Arguments | Results | SGBD comment |
|---|---|---|---|---|
CO_ABGLEICH_LESEN | 12 05 40 01 | – | STAT_CO_ABGLEICH_WERT | CO-Abgleich lesen |
LL_ABGLEICH_LESEN | 12 05 40 02 | – | STAT_LL_ABGLEICH_WERT, STAT_LL_ABGLEICH_WERT_UMGER | LL-Abgleich lesen |
VERBRAUCH_ABGLEICH_LESEN | 12 05 40 0A | – | STAT_VERBRAUCH_ABGLEICH_WERT | Korrekturfaktor Verbrauchsanzeige lesen |
CO_ABGLEICH_VERSTELLEN | 12 06 41 01 xx | CO_ABGLEICH_VERSTELLEN_WERT | – | CO-Drehzahl verstellen |
LL_ABGLEICH_VERSTELLEN | 12 06 41 02 xx | LL_ABGLEICH_VERSTELLEN_WERT | – | LL-Drehzahl verstellen |
VERBRAUCH_ABGLEICH_VERSTELLEN | 12 06 41 0A xx | VERBRAUCH_ABGLEICH_VERSTELLEN_WERT | – | Korr.-Faktor Verbrauchsanzeige verstellen |
VERBRAUCH_ABGLEICH_VERWERFEN | 12 06 41 0A xx | – | – | Korr.-Faktor Verbrauch verwerfen |
CO_ABGLEICH_PROGRAMMIEREN | 12 05 42 01 | – | CO_ABGLEICH_PROGRAMMIEREN_STATUS | CO-Drehzahl Abgleich programmieren |
LL_ABGLEICH_PROGRAMMIEREN | 12 05 42 02 | – | LL_ABGLEICH_PROGRAMMIEREN_STATUS | LL-Drehzahl Abgleich programmieren |
VERBRAUCH_ABGLEICH_PROGRAMMIEREN | – | – | VERBRAUCH_ABGLEICH_PROGRAMMIEREN_STATUS | Globale Variable zuruecksetzen |
Adaptation and counter resets (13)
| Job | Request | Arguments | Results | SGBD comment |
|---|---|---|---|---|
ADAPT_LOESCHEN | 12 06 43 FF FF | – | – | Adaptionen loeschen |
ADAPT_LAUFUNRUHE_LOESCHEN ¹ | 12 06 43 80 00 | – | – | Adaption Laufunruhe loeschen |
ADAPT_SCHLIESSZEIT_LOESCHEN ¹ | 12 06 43 40 00 | – | – | Adaption Laufunruhe loeschen |
ADAPT_LM_SENSOR_LOESCHEN ¹ | 12 06 43 10 00 | – | – | Adaption LM-Hoehensensor loeschen |
ADAPT_DROSSELKLAPPE_LOESCHEN ¹ | 12 06 43 08 00 | – | – | Adaption Drosselklappe loeschen |
ADAPT_LAMBDA_LOESCHEN ¹ | 12 06 43 04 00 | – | – | Adaption Lambda loeschen |
ADAPT_LEERLAUF_LOESCHEN ¹ | 12 06 43 02 00 | – | – | Adaption Leerlauffuellsteller loeschen |
ADAPT_KLOPFREGELUNG_LOESCHEN ¹ | 12 06 43 01 00 | – | – | Adaption Klopfregelung loeschen |
ADAPT_VARIANTEN_LOESCHEN ¹ | 12 06 43 00 01 | – | – | Adaption Varianten loeschen |
KW_GEBER_FEHLER_RUECKSETZEN | 12 08 90 42 4D 57 xx12 09 07 12 00 00 00 0012 08 90 xx xx xx xx | – | STAT_SEED_KEY, Z_ZAHL, STAT_KW_GEBER_FEHLER_RUECKSETZEN_WERT, STAT_KW_GEBER_FEHLER_RUECKSETZEN_TEXT | KW-Geber Fehler ruecksetzen |
FUSSHEBELFEHLBEDIENUNG_LOESCHEN | 12 05 44 02 | – | – | Eintraege Fusshebelfehlbedienung loeschen |
ABSCHALTBEDINGUNG_FGR_LOESCHEN | 12 05 44 03 | – | – | Eintraege Fusshebelfehlbedienung loeschen |
KW_GEBER_FEHLER_LESEN | 12 09 06 00 xx xx xx xx | – | – | RAM - Zellen KW-Fehleranalyse auslesen |
EWS 3 (4)
| Job | Request | Arguments | Results | SGBD comment |
|---|---|---|---|---|
STATUS_PROG_STAT_EWS | 12 05 0B 95 | – | STAT_PROG_STAT_EWS_WERT, STAT_PROG_STAT_EWS_TEXT | Status Schalteingaenge |
MEHRFACHSTARTWERTABGLEICH | 12 09 07 27 00 00 00 00 | – | STAT_MEHRFACHSTARTWERTABGLEICH_WERT, STAT_MEHRFACHSTARTWERTABGLEICH_TEXT | Mehrfachstartwertabgleich des EWS in den Werken |
STEUERN_SYNC_MODE ¹ | 12 05 6C 01 | MODE | STEUERN_SYNC_MODE_STATUS, STEUERN_SYNC_MODE_TEXT | Synchronisation EWS |
STATUS_SYNC_MODE ¹ | 12 04 6D | – | STAT_SYNC_MODE_STATUS, STAT_SYNC_MODE_TEXT | Status EWS auslesen |